Abstract: The determination of the critical ventilation flow rate is significant for risk control and standard development during accidental hydrogen leakage in a confined space with hydrogen-related equipment. This paper presents an analytical model for calculating the critical ventilation flow rate through the quantification and constraint solution of the ventilation effect and ventilation cost. The experimental method was used to investigate the effects of nozzle diameter and stagnation pressure on the diffusion and ventilation of horizontal hydrogen leakage in a cuboid chamber. Ventilations from 30 to 180 m3/h were carried out through the rectangular vent. It was shown that the peak concentration of the measuring point was positively correlated with the stagnation pressure and the nozzle diameter. The experimental data were used to verify the analytical model by calculating the effective ventilation time. This study demonstrates that the critical ventilation flow rate can be increased significantly at higher stagnation pressures and larger nozzle diameters. Furthermore, the discrepancy of critical ventilation flow rates under different nozzle diameters will be enhanced with the increase of stagnation pressure. For a stagnation pressure of 0.4 MPa, the critical ventilation flow rate under a 4 mm nozzle even increased by 52% relative to the 2 mm nozzle.
Keywords: Analytical model
Forced ventilation
Hydrogen leakage
Ventilation flow rate
Publisher: MDPI AG
Journal: Energies 
EISSN: 1996-1073
DOI: 10.3390/en16196864
Rights: © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
The following publication Sun X, Yang J, Wang J, Chen X, Shi J. Analytical Model of Critical Ventilation Flow Rate for Accidental Hydrogen Leakage in a Confined Space. Energies. 2023; 16(19):6864 is available at https://doi.org/10.3390/en16196864.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
energies-16-06864.pdf15.64 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

89
Citations as of Nov 10, 2025

Downloads

36
Citations as of Nov 10, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.