Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/108661
| Title: | Evaluation of a restoration algorithm applied to clipped tibial acceleration signals | Authors: | Chan, ZYS Angel, C Thomson, D Ferber, R Tsang, SMH Cheung, RTH |
Issue Date: | May-2023 | Source: | Sensors, May 2023, v. 23, no. 10, 4609 | Abstract: | Wireless accelerometers with various operating ranges have been used to measure tibial acceleration. Accelerometers with a low operating range output distorted signals and have been found to result in inaccurate measurements of peaks. A restoration algorithm using spline interpolation has been proposed to restore the distorted signal. This algorithm has been validated for axial peaks within the range of 15.0–15.9 g. However, the accuracy of peaks of higher magnitude and the resultant peaks have not been reported. The purpose of the present study is to evaluate the measurement agreement of the restored peaks using a low-range accelerometer (±16 g) against peaks sampled using a high-range accelerometer (±200 g). The measurement agreement of both the axial and resultant peaks were examined. In total, 24 runners were equipped with 2 tri-axial accelerometers at their tibia and completed an outdoor running assessment. The accelerometer with an operating range of ±200 g was used as reference. The results of this study showed an average difference of −1.40 ± 4.52 g and −1.23 ± 5.48 g for axial and resultant peaks. Based on our findings, the restoration algorithm could skew data and potentially lead to incorrect conclusions if used without caution. | Keywords: | Accelerometer Interpolation Operating range Peak tibial acceleration Wearable sensors |
Publisher: | MDPI AG | Journal: | Sensors | EISSN: | 1424-8220 | DOI: | 10.3390/s23104609 | Rights: | © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). The following publication Chan ZYS, Angel C, Thomson D, Ferber R, Tsang SMH, Cheung RTH. Evaluation of a Restoration Algorithm Applied to Clipped Tibial Acceleration Signals. Sensors. 2023; 23(10):4609 is available at https://doi.org/10.3390/s23104609. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| sensors-23-04609.pdf | 3.08 MB | Adobe PDF | View/Open |
Page views
83
Citations as of Nov 10, 2025
Downloads
23
Citations as of Nov 10, 2025
SCOPUSTM
Citations
2
Citations as of Dec 19, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.