Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/108133
PIRA download icon_1.1View/Download Full Text
Title: Response surface modeling and optimization scheme of an internally cooled liquid desiccant air conditioning system
Authors: Zhang, Y 
Zhang, H 
Yang, H 
Chen, Y
Leung, CW 
Issue Date: 1-Oct-2023
Source: Journal of building engineering, 1 Oct. 2023, v. 76, 107371
Abstract: Applying an internally cooled liquid desiccant air conditioning system (LDAC) is a promising energy-saving and emission-reduction scheme for hot and humid areas. This research investigates the application of an internally cooled LDAC for performance enhancement in hot and humid areas like Hong Kong. The combined system integrates liquid desiccant dehumidification (LDD) and regenerative indirect evaporative cooling (RIEC) without a power-intensive compressor. The internally cooled LDD removes latent heat from the hot and humid air before the RIEC cools it. To ensure efficient energy utilization, the LDD captures the exhaust air to assist in the dehumidification and initial cooling of the fresh air, which alleviates the efficiency deterioration of the desiccant. An all-fresh air system is used for better indoor air quality. To optimize the performance of a system with many influencing parameters, the response surface method (RSM) and multi-objective optimization are used to optimize and assess the potential and performance of the system. The system cooling capacity (C), latent heat removal rate (Qd), and dehumidification efficiency (ηd) are used as the optimization objectives. The response surface model and desirability function approach optimize six critical parameters, achieving a 7.6% improvement in dehumidification performance with low airspeed (1.5 m/s) and high desiccant concentration (40%) during high-humidity months. Increasing the extraction ratio of the RIEC by 20% in warmer months enhances the peak cooling capacity by 23.6%. This research contributes to implementing internally cooled LDAC systems and provides insights into optimizing monthly operation patterns in hot and humid regions.
Keywords: Indirect evaporative cooling
Liquid desiccant dehumidification
Response surface method
System optimization
Publisher: Elsevier
Journal: Journal of building engineering 
EISSN: 2352-7102
DOI: 10.1016/j.jobe.2023.107371
Rights: © 2023 Elsevier Ltd. All rights reserved.
© 2023. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Zhang, Y., Zhang, H., Yang, H., Chen, Y., & Leung, C. W. (2023). Response surface modeling and optimization scheme of an internally cooled liquid desiccant air conditioning system. Journal of Building Engineering, 76, 107371 is available at https://doi.org/10.1016/j.jobe.2023.107371.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Zhang_Response_Surface_Modeling.pdfPre-Published version3.7 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

58
Citations as of Nov 10, 2025

SCOPUSTM   
Citations

15
Citations as of Dec 5, 2025

WEB OF SCIENCETM
Citations

14
Citations as of Dec 4, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.