Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/108124
PIRA download icon_1.1View/Download Full Text
Title: Spray parameter analysis and performance optimization of indirect evaporative cooler considering surface wettability
Authors: Ma, X 
Shi, W 
Yang, H 
Issue Date: 1-Apr-2024
Source: Journal of building engineering, 1 Apr. 2024, v. 82, 108175
Abstract: Along with the increasing energy consumption of space cooling, the building industry is in urgent need of the environmental-friendly and proven cooling technology. Indirect evaporative cooling (IEC) is attracting wider attention as a sustainable technology based on the heat absorption properties of evaporation. It has been demonstrated that the plate surface covered by the water membrane in the wet channels has a substantial effect on the operating performance in the practical use of IEC technology, while the ideal state of the uniform water distribution assumed by existing models is usually difficult to be achieved. In order to enhance the evaporation process, it is crucial to tune the nozzle features in water supply session and organize the nozzles suitably over the heat exchanger. In this study, a three-dimensions Computational Fluid Dynamics (CFD) model is therefore proposed, which considers the actual wetting factor of the plate surface. In addition, the movement of the spray droplets as well as the formation and flow state of the water film covering the plate surface, are reflected in the simulation model to predict the performance of the IEC under normal operation more accurately. The results depicted that the maximum coverage area could be achieved when the diameter of the spray droplet maintains 0.25 mm with the flow rate is 5.4 L/min, and the distance between two nozzles is 80 mm. Besides, the maximum value of the wet-bulb efficiency and the coefficient of performance (COP) of the IEC system with optimised nozzle parameter settings could be improved up to 15.1 % and 17.6 % respectively compared to the conventional one. The proposed 3D model could contribute to the improvement of further IEC technique by providing a homogeneity of the water film covered on the plate surface to reflect future research into the heat and mass transfer mechanisms of hydrophilic materials.
Keywords: CFD model
Indirect evaporative cooler
Nozzle settings
Optimization
Wettability
Publisher: Elsevier
Journal: Journal of building engineering 
EISSN: 2352-7102
DOI: 10.1016/j.jobe.2023.108175
Rights: © 2023 Elsevier Ltd. All rights reserved.
© 2023. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Ma, X., Shi, W., & Yang, H. (2024). Spray parameter analysis and performance optimization of indirect evaporative cooler considering surface wettability. Journal of Building Engineering, 82, 108175 is available at https://doi.org/10.1016/j.jobe.2023.108175.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Ma_Spray_Parameter_Analysis.pdfPre-Published version1.79 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

109
Citations as of Feb 9, 2026

SCOPUSTM   
Citations

15
Citations as of May 8, 2026

WEB OF SCIENCETM
Citations

14
Citations as of Apr 23, 2026

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.