Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/108122
Title: Investigation on overall energy performance of a novel multi-functional PV/T window
Authors: Wang, C 
Yang, H 
Ji, J
Issue Date: 15-Dec-2023
Source: Applied energy, 15 Dec. 2023, v. 352, 122000
Abstract: PV windows are considered to be a promising building-integrated PV technology due to their excellent electrical, daylighting and thermal performance. However, the shading of the PV cells increases the heating load in winter and the high temperature of PV cells exacerbates the cooling load in summer. Moreover, a significant portion of the heat absorbed by the PV modules is usually wasted. To address these issues, this paper proposed a multi-functional PV/T window. This system could recover the heat on PV cells for producing warm air in winter and hot water in other seasons. As a result, the proposed system can realize the combined PV/T utilization of solar energy and reduce the seasonal thermal needs of the building. First, the mathematical model of the proposed window was developed and validated. Next, the developed model was integrated into building energy software to evaluate the overall energy performance of the proposed window in four different cities of Yangtze River region: Shanghai, Nanjing, Wuhan, and Chongqing in China. These cities experience the subtropical humid climate (Cfa in the Köppen-Geiger classification) and belong to the zones with medium global horizontal irradiation. The sensitivity analysis revealed that the optimal slat angles are between 0o and 40o, while the optimal orientation angles range from 30o to 60o. Selecting low-iron glass as the inner glass resulted in the lowest overall energy consumption. By adopting the MFPV/T window, the annual operation cost of the studied case could be reduced by 34% (6.4 $/m2), 36% (7.0 $/m2), 28% (5.7 $/m2), and 16% (2.9 $/m2) in these four cites, respectively. Additionally, the annual CO2 emissions could be curtailed by 53.5, 58.5, 47, and 22.3 kg/m2, respectively.
Keywords: Building energy saving
Double-skin window
PV/T
Sensitivity analysis
Yangtze River region
Publisher: Pergamon Press
Journal: Applied energy 
ISSN: 0306-2619
EISSN: 1872-9118
DOI: 10.1016/j.apenergy.2023.122000
Appears in Collections:Journal/Magazine Article

Open Access Information
Status embargoed access
Embargo End Date 2025-12-15
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

100
Citations as of Nov 10, 2025

SCOPUSTM   
Citations

16
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

14
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.