Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/108096
PIRA download icon_1.1View/Download Full Text
Title: Numerical analysis of the mitigation performance of a buried PT-WIB on environmental vibration
Authors: Gao, L 
Cai, C
Li, C
Mak, CM 
Issue Date: Sep-2023
Source: Sensors, Sept 2023, v. 23, no. 18, 7666
Abstract: Environmental vibration pollution has serious negative impacts on human health. Among the various contributors to environmental vibration pollution in urban areas, rail transit vibration stands out as a significant source. Consequently, addressing this issue and finding effective measures to attenuate rail transit vibration has become a significant area of concern. An infilled trench can be arranged periodically along the propagation paths of the waves in the soil to attenuate vibration waves in a specific frequency range. However, the periodic infilled trench seems to be unsatisfactory for providing wide band gaps at low and medium frequencies. To improve the isolation performance of wave barriers at low to medium frequencies, a buried PT-WIB consisting of a periodic infilled trench and a wave impedance block barrier has been proposed in this paper. A three-dimensional finite element model has been developed to evaluate the isolation performance of three wave barriers. The influence of the PT-WIB’s parameters on isolation performance has been analyzed. The results indicate that the combined properties of the periodic structure and the wave impedance block barrier can effectively achieve a wide attenuation zone at low and medium frequencies, enhancing the isolation performance for mitigating environmental vibration pollution.
Keywords: Attenuation zone
Environmental vibration
Finite element
Periodic structure
Wave impedance block
Publisher: MDPI AG
Journal: Sensors 
EISSN: 1424-8220
DOI: 10.3390/s23187666
Rights: © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
The following publication Gao L, Cai C, Li C, Mak CM. Numerical Analysis of the Mitigation Performance of a Buried PT-WIB on Environmental Vibration. Sensors. 2023; 23(18):7666 is available at https://doi.org/10.3390/s23187666.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
sensors-23-07666-v3.pdf3.02 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

96
Citations as of Nov 10, 2025

Downloads

17
Citations as of Nov 10, 2025

SCOPUSTM   
Citations

4
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

5
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.