Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/107663
PIRA download icon_1.1View/Download Full Text
Title: Model generalizability investigation for GFCE-MRI synthesis in NPC radiotherapy using multi-institutional patient-based data normalization
Authors: Li, W 
Lam, S 
Wang, Y 
Liu, C 
Li, T 
Kleesiek, J
Cheung, ALY 
Sun, Y
Lee, FKH
Au, KH
Lee, VHF
Cai, J 
Issue Date: Jan-2024
Source: IEEE journal of biomedical and health informatics, Jan. 2024, v. 28, no. 1, p. 100-109
Abstract: Recently, deep learning has been demonstrated to be feasible in eliminating the use of gadoliniumbased contrast agents (GBCAs) through synthesizing gadolinium-free contrast-enhanced MRI (GFCE-MRI) from contrast-free MRI sequences, providing the community with an alternative to get rid of GBCAs-associated safety issues in patients. Nevertheless, generalizability assessment of the GFCE-MRI model has been largely challenged by the high inter-institutional heterogeneity of MRI data, on top of the scarcity of multi-institutional data itself. Although various data normalization methods have been adopted to address the heterogeneity issue, it has been limited to single-institutional investigation and there is no standard normalization approach presently. In this study, we aimed at investigating generalizability of GFCE-MRI model using data from seven institutions by manipulating heterogeneity of MRI data under five popular normalization approaches. Three state-of-the-art neural networks were applied to map from T1-weighted and T2-weighted MRI to contrast-enhanced MRI (CE-MRI) for GFCE-MRI synthesis in patients with nasopharyngeal carcinoma. MRI data from three institutions were used separately to generate three uni-institution models and jointly for a tri-institution model. The five normalization methods were applied to normalize the data of each model. MRI data from the remaining four institutions served as external cohorts for model generalizability assessment. Quality of GFCE-MRI was quantitatively evaluated against ground-truth CE-MRI using mean absolute error (MAE) and peak signal-to-noise ratio(PSNR). Results showed that performance of all uni-institution models remarkably dropped on the external cohorts. By contrast, model trained using multi-institutional data with Z-Score normalization yielded the best model generalizability improvement.
Keywords: Contrast enhanced MRI
Data normalization
Nasopharyngeal carcinoma
Publisher: Institute of Electrical and Electronics Engineers
Journal: IEEE journal of biomedical and health informatics 
ISSN: 2168-2194
EISSN: 2168-2208
DOI: 10.1109/JBHI.2023.3308529
Rights: © 2023 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
The following publication W. Li et al., "Model Generalizability Investigation for GFCE-MRI Synthesis in NPC Radiotherapy Using Multi-Institutional Patient-Based Data Normalization," in IEEE Journal of Biomedical and Health Informatics, vol. 28, no. 1, pp. 100-109, Jan. 2024 is available at https://doi.org/10.1109/JBHI.2023.3308529.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Li_Model_Generalizability_Investigation.pdfPre-Published version3.39 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

41
Citations as of Apr 14, 2025

Downloads

59
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

7
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

5
Citations as of Jan 9, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.