| Title: | Time-domain PEEC transient analysis for a wire structure above the perfectly conducting ground with the incident field from a distant lightning channel | Authors: | Qi, R Du, YP Chen, M |
Issue Date: | Oct-2020 | Source: | IEEE transactions on electromagnetic compatibility, Oct. 2020, v. 62, no. 5, p. 1787-1795 | Abstract: | This paper presents the time-domain partial element equivalent circuit (PEEC) analysis of induced transients in a wire structure during an indirect lightning strike. The full-wave PEEC formulation with an external incident field is employed. The incident field is calculated with either the Uman's or the Jefimenko's formula by using the engineering model of a lightning channel. An instability problem is, however, observed. It becomes a hurdle in the application of PEEC for evaluating induced transient currents in closed wire loops. The problem is investigated, and is primarily caused by discretization of the electric field in numerical evaluation of external voltage sources. An algorithm is provided to solve this instability problem, and is tested for both near-and far-field cases. It is validated by the finite-difference time-domain method. The issue of time step and segment length is addressed. It is also found that the Uman's formula is generally incapable of producing stable induced currents in a wire loop structure. Finally, the proposed PEEC procedure is applied to evaluate induced lightning transients in a photovoltaic panel during an indirect lightning strike. | Keywords: | Induced transient Lightning Partial element equivalent circuit (PEEC) Wire |
Publisher: | Institute of Electrical and Electronics Engineers | Journal: | IEEE transactions on electromagnetic compatibility | ISSN: | 0018-9375 | EISSN: | 1558-187X | DOI: | 10.1109/TEMC.2019.2925140 | Rights: | © 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The following publication Qi, R., Du, Y. P., & Chen, M. (2019). Time-domain PEEC transient analysis for a wire structure above the perfectly conducting ground with the incident field from a distant lightning channel. IEEE Transactions on Electromagnetic Compatibility, 62(5), 1787-1795 is available at https://doi.org/10.1109/TEMC.2019.2925140. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Qi_Time-Domain_PEEC_Transient.pdf | Pre-Published version | 1.11 MB | Adobe PDF | View/Open |
Page views
123
Last Week
6
6
Last month
Citations as of Nov 9, 2025
Downloads
76
Citations as of Nov 9, 2025
SCOPUSTM
Citations
18
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
16
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.