Title: Adopting ‘lift-up’ building design to improve the surrounding pedestrian-level wind environment
Authors: Tse, KT
Zhang, X
Weerasuriya, AU
Li, SW
Kwok, KCS
Mak, CM 
Niu, J 
Issue Date: 15-May-2017
Source: Building and environment, 15 May 2017, v. 117, p. 154-165
Abstract: Modern megacities are teeming with closely-spaced tall buildings, which limit air circulation at the pedestrian level. The resultant lack of air circulation creates poorly ventilated areas with accumulated air pollutants and thermal discomfort in the summer. To improve air circulation at the pedestrian level, buildings may be designed to have a ‘lift-up’ shape, in which the main structure is supported by a central core, columns or shear walls. However, a lack of knowledge on the influence of the ‘lift-up’ design on the surrounding wind environment limits the use of ‘lift-up’ buildings. This study aims to investigate the influence of ‘lift-up’ buildings and their dimensions on the pedestrian-level wind environments using wind tunnel tests. A parametric study was undertaken by using 9 ‘lift-up’ building models with different core heights and widths. The results were compared with the surrounding wind environment of a control building with similar dimensions. The results reveal that the ‘lift-up’ core height is the most influential parameter and governs the area and magnitude of high and low wind speed zones around such buildings. Based on wind tunnel test results and a selected comfort criterion, appropriate core dimensions could be selected to have acceptable wind conditions near lift-up buildings.
Keywords: Building dimensions
Pedestrian-level wind environment
Wind tunnel test
‘Lift-up’ building
‘Lift-up’ core dimensions
Publisher: Pergamon Press
Journal: Building and environment 
ISSN: 0360-1323
EISSN: 1873-684X
DOI: 10.1016/j.buildenv.2017.03.011
Rights: © 2017 Elsevier Ltd. All rights reserved.
© 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Tse, K. T., Zhang, X., Weerasuriya, A. U., Li, S. W., Kwok, K. C. S., Mak, C. M., & Niu, J. (2017). Adopting ‘lift-up’ building design to improve the surrounding pedestrian-level wind environment. Building and Environment, 117, 154-165 is available at https://doi.org/10.1016/j.buildenv.2017.03.011.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Mak_Adopting_Lift-up_Building.pdfPre-Published version1.94 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

116
Last Week
6
Last month
Citations as of Nov 9, 2025

Downloads

54
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

87
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

83
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.