| Title: | Developing a robust assessment system for the passive design approach in the green building rating scheme of Hong Kong | Authors: | Chen, X Yang, H Wang, T |
Issue Date: | 1-Jun-2017 | Source: | Journal of cleaner production, 1 June 2017, v. 153, p. 176-194 | Abstract: | This paper proposed a renovated passive design assessment system for green building labelling based on robust energy end-use statistics, different global sensitivity analysis methods, modelling experiments and a detailed case study. The developed system is only applied to cooling and lighting related criteria, which are mainly influenced by selected passive design strategies. After a preliminary definition of the assessment framework and total available credits, the priorities of different sub-criteria are derived from sensitivity analyses of a generic building model with screening-based, variance-based and regression methods. Adjustment of assessment criteria is also performed according to significance tests and post optimization analyses. Furthermore, performance and grading scales are formulated with baseline requirements, optimization results and local sensitivity analyses. Eventually, the FAST (Fourier Amplitude Sensitivity Test) method is proved to generate the most appropriate weighting system considering the consistence of the credit prediction with the traditional whole building simulation approach. Findings from this research can guide decision-makers in the construction industry to obtain an optimized preliminary design by properly allocating resources and investments under a prescriptive evaluation approach starting from the early planning stage. The research design can also be applied to determine the assessment system for other performance-based criteria in a green building assessment scheme. | Keywords: | Assessment BEAM Green building Passive design Sensitivity analysis Weighting |
Publisher: | Elsevier | Journal: | Journal of cleaner production | ISSN: | 0959-6526 | DOI: | 10.1016/j.jclepro.2017.03.191 | Rights: | © 2017 Elsevier Ltd. All rights reserved. © 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/. The following publication Chen, X., Yang, H., & Wang, T. (2017). Developing a robust assessment system for the passive design approach in the green building rating scheme of hong kong. Journal of Cleaner Production, 153, 176-194 is available at https://doi.org/10.1016/j.jclepro.2017.03.191. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Yang_Developing_Robust_Assessment.pdf | Pre-Published version | 2.03 MB | Adobe PDF | View/Open |
Page views
88
Last Week
4
4
Last month
Citations as of Nov 9, 2025
Downloads
72
Citations as of Nov 9, 2025
SCOPUSTM
Citations
29
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
28
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.