Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/102945
| Title: | Evaluation of pedestrian wind comfort near ‘lift-up’ buildings with different aspect ratios and central core modifications | Authors: | Zhang, X Tse, KT Weerasuriya, AU Li, SW Kwok, KCS Mak, CM Niu, J Lin, Z |
Issue Date: | 1-Nov-2017 | Source: | Building and environment, 1 Nov. 2017, v. 124, p. 245-257 | Abstract: | Owing to the void space at lower heights, lift-up buildings have high building permeability at ground level and subsequently improve the air circulation in congested urban areas. Despite this advantage, the lift-up design has been sparsely adopted for buildings in urban areas partly because of the lack of understanding of the combined effects of building dimensions and lift-up design on the surrounding pedestrian level wind (PLW) field. Therefore, this study aims to investigate the influence of lift-up buildings with different aspect ratios (height/width) on the surrounding PLW field and pedestrian wind comfort level. Five lift-up buildings with aspect ratios 4:1 to 0.5:1 were tested in a boundary layer wind tunnel and results were compared with those of five buildings with similar dimensions but without lift-up design. The results reveal a strong dependence of the maximum wind speed in lift-up areas with building height, which results subsequently a small area of acceptable wind conditions near tall and slender lift-up buildings. Lift-up designs adopted for short and wide buildings produce larger areas of pedestrian wind comfort. The central cores modified with corner modifications are effective in increasing the pedestrian wind comfort in the lift-up area of tall and slender buildings. | Keywords: | Building dimension Corner modification Lift-up building Pedestrian wind comfort Wind tunnel test |
Publisher: | Pergamon Press | Journal: | Building and environment | ISSN: | 0360-1323 | EISSN: | 1873-684X | DOI: | 10.1016/j.buildenv.2017.08.012 | Rights: | © 2017 Elsevier Ltd. All rights reserved © 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/. The following publication Zhang, X., Tse, K. T., Weerasuriya, A. U., Li, S. W., Kwok, K. C. S., Mak, C. M., . . . Lin, Z. (2017). Evaluation of pedestrian wind comfort near ‘lift-up’ buildings with different aspect ratios and central core modifications. Building and Environment, 124, 245-257 is available at https://doi.org/10.1016/j.buildenv.2017.08.012. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Mak_Evaluation_Pedestrian_Wind.pdf | Pre-Published version | 1.51 MB | Adobe PDF | View/Open |
Page views
133
Last Week
5
5
Last month
Citations as of Nov 9, 2025
Downloads
68
Citations as of Nov 9, 2025
SCOPUSTM
Citations
87
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
82
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.