Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/102915
| Title: | Numerical study on the impact of runner inlet arc angle on the performance of inline cross-flow turbine used in urban water mains | Authors: | Du, J Shen, Z Yang, H |
Issue Date: | 1-Sep-2018 | Source: | Energy, 1 Sept. 2018, v. 158, p. 228-237 | Abstract: | The inline cross-flow turbine is a promising and reliable device to harvest hydropower in an urban water supply pipeline for power supply to its water supply monitoring system. However, investigations about the influencing factors on the performance of inline cross-flow turbines are still rare and this paper focuses on the effect of their runner inlet arc angle for improving the device's performance. Firstly, a mathematical design method for the turbine's blocks is developed. With the proposed method, four models with different runner inlet arc angles are developed. The turbine's performance, function of conversion block, flow velocity characteristics, pressure distribution and blades torque output of the models are then analyzed. Results indicate that a smaller runner inlet arc can increase the flow velocity at runner inlet and pressure difference between the upstream and downstream of the runner, resulting in a higher output power but also a higher overall water head reduction through the turbine. Besides, it is found that the runner inlet arc angle has a significant influence on the power output of runner second stage. With the increase of runner inlet arc angle, the torque output at the second stage encounters a gradual decrease. To achieve a good balance between turbine efficiency and water head reduction, the suggested runner inlet arc angle is 105°. Numerical results showed that the model with 105° runner inlet arc angle could produce a maximum power generation efficiency of 42.6% with about 1.6 kW power output. | Keywords: | Inline cross-flow turbine Micro hydropower Runner inlet arc angle Urban water mains |
Publisher: | Pergamon Press | Journal: | Energy | ISSN: | 0360-5442 | EISSN: | 1873-6785 | DOI: | 10.1016/j.energy.2018.06.033 | Rights: | © 2018 Elsevier Ltd. All rights reserved. © 2018. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/. The following publication Du, J., Shen, Z., & Yang, H. (2018). Numerical study on the impact of runner inlet arc angle on the performance of inline cross-flow turbine used in urban water mains. Energy, 158, 228-237 is available at https://doi.org/10.1016/j.energy.2018.06.033. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Yang_Numerical_Study_Impact.pdf | Pre-Published version | 2.09 MB | Adobe PDF | View/Open |
Page views
76
Last Week
3
3
Last month
Citations as of Nov 9, 2025
Downloads
82
Citations as of Nov 9, 2025
SCOPUSTM
Citations
22
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
20
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.



