Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/102907
PIRA download icon_1.1View/Download Full Text
Title: Numerical investigation of a novel vacuum photovoltaic curtain wall and integrated optimization of photovoltaic envelope systems
Authors: Huang, J 
Chen, X 
Yang, H 
Zhang, W 
Issue Date: 1-Nov-2018
Source: Applied energy, 1 Nov. 2018, v. 229, p. 1048-1060
Abstract: This study presents a comprehensive investigation of the thermal and power performance of a novel vacuum photovoltaic insulated glass unit (VPV IGU) as well as an integrated design optimization of photovoltaic envelope systems. A prototype office building model with a curtain wall design is first constructed in EnergyPlus to compare the heat gain, heat loss, thermal load, lighting energy and PV generation for different curtain walls. The comparative analysis proves the excellent thermal insulating performance of VPV IGU, which can reduce up to 81.63% and 75.03% of the heat gain as well as 31.94% and 32.03% of the heat loss in Hong Kong (HK) and Harbin (HB) respectively. With the application of VPV IGU in all available facades of the prototype building, net energy savings of 37.79% and 39.82% can be achieved in diverse climatic conditions. Furthermore, screening and variance based sensitivity analyses are conducted to prioritize building integrated photovoltaic design parameters with respect to specific weather conditions. The selected important design parameters are then optimized with the non-dominated sorting genetic algorithm-II (NSGA-II), by which the optimum building design can achieve a net energy consumption reduction of 48.72% and 60.80% compared to benchmarking designs in Hong Kong and Harbin. Such an integrated design optimization can successfully improve computation efficiency with an acceptable solution accuracy, and assist the incorporation of PV envelop systems with passive architectural designs. The novel VPV IGU is determined to be more suitable for cold areas where the curtain wall design should also be avoided for energy conservation.
Keywords: Design optimization
Energy saving
Envelope system
Sensitivity analysis
Vacuum photovoltaic
Publisher: Pergamon Press
Journal: Applied energy 
ISSN: 0306-2619
EISSN: 1872-9118
DOI: 10.1016/j.apenergy.2018.08.095
Rights: © 2018 Elsevier Ltd. All rights reserved.
© 2018. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Huang, J., Chen, X., Yang, H., & Zhang, W. (2018). Numerical investigation of a novel vacuum photovoltaic curtain wall and integrated optimization of photovoltaic envelope systems. Applied Energy, 229, 1048-1060 is available at https://doi.org/10.1016/j.apenergy.2018.08.095.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Huang_Numerical_Investigation_Novel.pdfPre-Published version1.17 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

78
Last Week
4
Last month
Citations as of Nov 9, 2025

Downloads

126
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

60
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

54
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.