Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/102627
| Title: | Transient frequency response based leak detection in water supply pipeline systems with branched and looped junctions | Authors: | Duan, HF | Issue Date: | 1-Jan-2017 | Source: | Journal of hydroinformatics, 1 Jan. 2017, v. 19, no. 1, p. 17-30 | Abstract: | The transient frequency response (TFR) method has been widely developed and applied in the literature to identify and detect potential defects such as leakage and blockage in water supply pipe systems. This type of method was found to be efficient, economic and non-intrusive for pipeline condition assessment and diagnosis, but its applications so far are mainly limited to single and simple pipeline systems. This paper aims to extend the TFR-based leak detection method to relatively more complex pipeline connection situations. The branched and looped pipe junctions are firstly investigated for their influences to the system TFR, so that their effects can be characterized and separated from the effect of other components and potential leakage defects in the system. The leak-induced patterns of transient responses are derived analytically using the transfer matrix method for systems with different pipe junctions, which thereafter are used for the analysis of pipe leakage conditions in the system. The developed method is validated through different numerical experiments in this study. Based on the analytical analysis and numerical results, the applicability and accuracy as well as the limitations of the developed TFR-based leak detection method are discussed for practical applications in the paper. | Keywords: | Leak detection Pipe junction Transfer matrix Transient frequency response Transient tests Water pipeline system |
Publisher: | International Water Association Publishing | Journal: | Journal of hydroinformatics | ISSN: | 1464-7141 | EISSN: | 1465-1734 | DOI: | 10.2166/hydro.2016.008 | Rights: | © IWA Publishing 2017 This is the accepted manuscript of the following article: Huan-Feng Duan; Transient frequency response based leak detection in water supply pipeline systems with branched and looped junctions. Journal of Hydroinformatics 1 January 2017; 19 (1): 17–30, which has been published in final form at https://doi.org/10.2166/hydro.2016.008. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Duan_Transient_Frequency_Response.pdf | Pre-Published version | 1.5 MB | Adobe PDF | View/Open |
Page views
124
Last Week
4
4
Last month
Citations as of Nov 9, 2025
Downloads
228
Citations as of Nov 9, 2025
SCOPUSTM
Citations
80
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
77
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.



