Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/100722
PIRA download icon_1.1View/Download Full Text
Title: Imaging and condition diagnosis of underground sewer liners via active and passive infrared thermography : a case study in Singapore
Authors: Sham, JFC 
Lai, WWL 
Chan, W
Koh, CL
Issue Date: Feb-2019
Source: Tunnelling and underground space technology, Feb. 2019, v. 84, p. 440-450
Abstract: This paper presents a case study of customizing an in-house built In-pipe Infrared Thermographic System (IPITS), which makes use of thermo-images for imaging and diagnosis of pipe crown condition in underground sewer pipelines. Active and passive infrared thermography (IRT) were attempted in two gravity sewer pipes in Singapore in July 2017. The results show that images captured with active IRT (with heating) can image and reveal invisible lining defects not readily revealed by traditional visual inspection using CCTV. These defects include bubbles, wrinkling and delamination, or construction details (like anchor knobs in HDPE material), for which sizes were estimated using an image processing algorithm customized in an in-house program. While images captured by passive IRT (without heating) can be used to identify suspected water seeping points, this paper also reports the design of instrumentation and appropriate parameter settings. The results of this case study are believed to pave the way for parallel inspections using a combination of CCTV and infrared cameras.
Keywords: Condition assessment
Defect identification
Infrared thermography
Sewer liners
Publisher: Pergamon Press
Journal: Tunnelling and underground space technology 
ISSN: 0886-7798
DOI: 10.1016/j.tust.2018.11.013
Rights: © 2018 Elsevier Ltd. All rights reserved.
© 2018. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Sham, J. F. C., Lai, W. W. L., Chan, W., & Koh, C. L. (2019). Imaging and condition diagnosis of underground sewer liners via active and passive infrared thermography: a case study in Singapore. Tunnelling and Underground Space Technology, 84, 440-450 is available at https://doi.org/10.1016/j.tust.2018.11.013.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Sham_Imaging_Condition_Diagnosis.pdfPre-Published version2.66 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

86
Citations as of Apr 14, 2025

Downloads

87
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

18
Citations as of Sep 12, 2025

WEB OF SCIENCETM
Citations

12
Citations as of Oct 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.