Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/100598
PIRA download icon_1.1View/Download Full Text
Title: Investigation on economic and reliable operation of meshed MTDC/AC grid as impacted by offshore wind farms
Authors: Bu, SQ 
Du, W
Wang, HF
Liu, Y
Liu, X
Issue Date: Sep-2017
Source: IEEE transactions on power systems, Sept. 2017, v. 32, no. 5, p. 3901-3911
Abstract: The influence of complementarity balancing connected grid and control of offshore wind power generation on the economic and reliable operation of hybrid multiterminal HVDC (MTDC) and AC power system is investigated in the paper. The variances of distribution curve of both transmission loss of AC/DC system and voltage of critical nodes assessed by cumulant-based method are used to demonstrate how the different complementarity conditions, generation balancing strategies, MTDC grid topologies, and control schemes affect power system operation. In this paper, a study case of 16-generator 68-bus power system connected with three offshore wind farms is presented. The variance indices of transmission loss and voltage magnitude are calculated and then compared under different complementarity levels, active power balancing strategies, HVDC transmission systems, and controls, respectively. The analysis reveals that higher complementarity and multi-machine balancing strategy can effectively reduce system operational cost and enhance operational reliability. Compared to the point-to-point topology, the control pattern and parameter setting of multi-terminal topology are two key factors to determine its impact on system operation.
Keywords: Balancing
Complementarity
Cumulant
Multi-terminal HVDC
Offshore wind power generation
System operation
Variance indices
Publisher: Institute of Electrical and Electronics Engineers
Journal: IEEE transactions on power systems 
ISSN: 0885-8950
EISSN: 1558-0679
DOI: 10.1109/TPWRS.2016.2636181
Rights: ©2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
The following publication S. Q. Bu, W. Du, H. F. Wang, Y. Liu and X. Liu, "Investigation on Economic and Reliable Operation of Meshed MTDC/AC Grid as Impacted by Offshore Wind Farms," in IEEE Transactions on Power Systems, vol. 32, no. 5, pp. 3901-3911, Sept. 2017 is available at https://doi.org/10.1109/TPWRS.2016.2636181.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Bu_Investigation_Economic_Reliable.pdfPre-Published version1.57 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

55
Citations as of Apr 14, 2025

Downloads

45
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

33
Citations as of Sep 12, 2025

WEB OF SCIENCETM
Citations

22
Citations as of Oct 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.