Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/109885
PIRA download icon_1.1View/Download Full Text
Title: Electric field-induced deterioration of cement mortars owing to calcium leaching
Authors: Huang, Q
Liu, H
Wang, Q
Shan, Y
Tang, D
Zhang, Z
Zhu, X 
Issue Date: Mar-2024
Source: Developments in the built environment, Mar. 2024, v. 17, 100303
Abstract: This paper investigated the calcium leaching from plain and fly ash/limestone blended cement mortars under an electric field. The Ca2+ leaching degree and reduced CaO content were measured to assess the extent of calcium leaching, and the compressive strength loss was used as an indicator to evaluate the degradation of the mortars due to leaching. Additionally, the changes in mineralogical composition, micrograph, Ca/Si ratio of C–S–H gel, and pore structure of leached samples were analyzed through X-ray diffraction (XRD), scanning electron microscopy (SEM/EDS), and mercury intrusion porosimetry (MIP). The findings indicated a notable acceleration in the leaching of Ca2+ due to the application of an electric field. Consequently, the calcium leaching degree of mortars continuously increased with time. The accelerated calcium leaching resulted in the loose microstructure and increased porosity mainly for the cathode part as well as the reduction in compressive strength of mortars. The addition of fly ash was beneficial in reducing the calcium leaching and strength loss of mortars after 90 days of exposure to the electric field, contrary to the effects observed with the incorporation of limestone powders. Attention should be paid to the durability issues of cement-based materials induced by the electric field.
Keywords: Calcium leaching
Cement mortar
Electric field
Microstructure
Strength loss
Publisher: Elsevier Ltd
Journal: Developments in the built environment 
EISSN: 2666-1659
DOI: 10.1016/j.dibe.2023.100303
Rights: © 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync-nd/4.0/).
The following publication Huang, Q., Liu, H., Wang, Q., Shan, Y., Tang, D., Zhang, Z., & Zhu, X. (2024). Electric field-induced deterioration of cement mortars owing to calcium leaching. Developments in the Built Environment, 17, 100303 is available at https://doi.org/10.1016/j.dibe.2023.100303.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
1-s2.0-S2666165923001850-main.pdf8.47 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.