Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/9813
Title: Analytical model of piezoelectric cantilever as rheological sensor
Authors: Yan, F 
Chan, HLW 
Keywords: Cantilever
Piezoelectric
Rheological sensor
Issue Date: 2011
Source: Physica B : Condensed matter, 2011, v. 406, no. 19, p. 3605-3608 How to cite?
Journal: Physica B: Condensed Matter 
Abstract: Cantilever sensors have attracted much attention due to their potential as a platform for the development of many physics, chemical, and biological sensors. An analytical model based on analyzing the equivalent circuit of a piezoelectric cantilever as a rheological sensor has been derived and applied in real test. This model can be used to significantly improve the resolution and detection range of the devices. Based on this model, piezoelectric cantilevers have been used for characterizing Newtonian oils with viscosity between 1 and 104 mPa s, and good agreements between experimental and modeled results have been obtained.
URI: http://hdl.handle.net/10397/9813
ISSN: 0921-4526
DOI: 10.1016/j.physb.2011.06.052
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query