Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/82311
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Building Services Engineering-
dc.creatorTang, L-
dc.creatorLiu, ZX-
dc.creatorZhou, Y-
dc.creatorQin, D-
dc.creatorZhang, GQ-
dc.date.accessioned2020-05-05T05:59:31Z-
dc.date.available2020-05-05T05:59:31Z-
dc.identifier.urihttp://hdl.handle.net/10397/82311-
dc.language.isoenen_US
dc.publisherMolecular Diversity Preservation International (MDPI)en_US
dc.rights© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).en_US
dc.rightsThe following publication Tang, L.; Liu, Z.; Zhou, Y.; Qin, D.; Zhang, G. Study on a Dynamic Numerical Model of an Underground Air Tunnel System for Cooling Applications—Experimental Validation and Multidimensional Parametrical Analysis. Energies 2020, 13, 1236 is available at https://dx.doi.org/10.3390/en13051236en_US
dc.subjectRenewable energyen_US
dc.subjectUnderground air tunnelen_US
dc.subjectDynamic modelen_US
dc.subjectCooling capacityen_US
dc.titleStudy on a dynamic numerical model of an underground air tunnel system for cooling applications-experimental validation and multidimensional parametrical analysisen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage1-
dc.identifier.epage20-
dc.identifier.volume13-
dc.identifier.issue5-
dc.identifier.doi10.3390/en13051236-
dcterms.abstractThe underground air tunnel system shows promising potentials for reducing energy consumption of buildings and for improving indoor thermal comfort, whereas the existing dynamic models using the computational fluid dynamic (CFD) method show computational complexity and are user-unfriendly for parametrical analysis. In this study, a dynamic numerical model was developed with the on-site experimental calibration. Compared to the traditional CFD method with high computational complexity, the mathematical model on the MATLAB/SIMULINK platform is time-saving in terms of the real-time thermal performance prediction. The experimental validation results indicated that the maximum absolute relative deviation was 3.18% between the model-driven results and the data from the on-site experiments. Parametrical analysis results indicated that, with the increase of the tube length, the outlet temperature decreases with an increase of the cooling capacity whereas the increasing/decreasing magnitude slows down. In addition, the system performance is independent on the tube materials. Furthermore, the outlet air temperature and cooling capacity are dependent on the tube diameter and air velocity, i.e., a larger tube diameter and a higher air velocity are more suitable to improve the system's cooling capacity, and a smaller tube diameter and a lower air velocity will produce a more stable and lower outlet temperature. Further studies need to be conducted for the trade-off solutions between air velocity and tube diameter for the bi-criteria performance enhancement between outlet temperature and cooling capacity. This study proposed an experimentally validated mathematical model to accurately predict the thermal performance of the underground air tunnel system with high computational efficiency, which can provide technical guidance to multi-combined solutions through geometrical designs and operating parameters for the optimal design and robust operation.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationEnergies, 1 Mar. 2020, v. 13, no. 5, 1236, p. 1-20-
dcterms.isPartOfEnergies-
dcterms.issued2020-
dc.identifier.isiWOS:000524318700223-
dc.identifier.scopus2-s2.0-85081731984-
dc.identifier.eissn1996-1073-
dc.identifier.artn1236-
dc.description.validate202006 bcrc-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_Scopus/WOSen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Tang_Dynamic_Numerical_Model.pdf4.08 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

86
Last Week
1
Last month
Citations as of Apr 14, 2024

Downloads

67
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

10
Citations as of Apr 12, 2024

WEB OF SCIENCETM
Citations

5
Citations as of Apr 18, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.