Title: A study of the " wall effect" caused by proliferation of high-rise buildings using GIS techniques
Authors: Wong, MS 
Nichol, J 
Ng, E
Keywords: Frontal area index
Geographic information systems
Thermal remote sensing
Ventilation
Wall effect
Issue Date: 2011
Publisher: Elsevier
Source: Landscape and urban planning, 2011, v. 102, no. 4, p. 245-253 How to cite?
Journal: Landscape and Urban Planning 
Abstract: This paper describes a novel method using Geographic Information Systems (GIS) to investigate the “wall effect” caused by proliferation of high-rise buildings along the coast in Kowloon Peninsula of Hong Kong. The research utilises the concept of building frontal area index which is calculated based on three dimensional buildings in 100 m grid cells. The main ventilation pathways across the urban area are located using Least Cost Path analysis in a raster GIS and validated by field measurements. Field measurements were also taken in front of windward and leeward buildings. Results show that winds are forced by high frontal area values, to deviate around coastlines with blocks of “wall effect” buildings parallel to the coast. Average wind speeds of 10.5 m s−1 were observed on the windward side of “wall effect” buildings defined according to a southeasterly wind direction, while average wind speeds immediately to the lee side of “wall effect” buildings as well as further inland, were approximately 2.5 m s−1 (four times lower). To confirm the “wall effect” hypothesis, scenario analysis was performed by removing these buildings from the model and re-running it. This revealed a 5% increase of air ventilation to urban areas inland, since more fresh onshore air is able to penetrate from the coast. This improvement is significant since only 0.05% of buildings in the study area were removed. Overlay of the ventilation pathways over a thermal satellite image representing Heat Island Intensity (HII) indicated significantly lower HII values, and reduced extent of the core HII areas, around the ventilation paths.
URI: http://hdl.handle.net/10397/8090
ISSN: 0169-2046
DOI: 10.1016/j.landurbplan.2011.05.003
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

14
Last Week
4
Last month
1
Citations as of Feb 26, 2017

WEB OF SCIENCETM
Citations

16
Last Week
0
Last month
Citations as of Aug 22, 2017

Page view(s)

49
Last Week
0
Last month
Checked on Aug 20, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.