Title: | Study on the optimization of PCM integrated air-conditioning duct for the demand shifting | Authors: | Hong, T Wang, S Wang, F Wang, X |
Issue Date: | 2019 | Source: | IOP conference series : earth and environmental science, 2019, v. 238, no. 1, 12045 | Abstract: | The imbalance of the electrical grid between source and demand causes great decrement of grid efficiency and energy loss. The main reason for the imbalance comes from the fluctuation of electricity consumed by buildings. Numerous efforts have been conducted to mitigate the fluctuation of buildings electricity consumption. The phase change material (PCM) can store heat or cold to keep indoor thermal environment stable for a certain period without heat/cold supply from heating, ventilation, and air-conditioning (HVAC) systems. It can effectively shave the peak of HVAC electricity demand. Meanwhile, the electricity cost of running HVAC systems can also be cut down. Therefore, this paper proposes a novel type of air-ducts integrated with PCM and studies its performances of the indoor thermal environment through theoretical analysis and dynamic simulation. The simulation results show that the indoor thermal environment can be kept within the comfortable range when turn off chiller during the peak load period using the proposed PCM integrated air conditioning ducts. | Publisher: | Institute of Physics Publishing | Journal: | IOP conference series : earth and environmental science | ISSN: | 1755-1307 | DOI: | 10.1088/1755-1315/238/1/012045 | Description: | 4th Asia Conference of International Building Performance Simulation Association, ASIM 2018, Hong Kong, 3-5 December 2018 | Rights: | Content from this work may be used under the terms of theCreative Commons Attribution 3.0 licence (https://creativecommons.org/licenses/by/3.0/). Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by IOP Publishing Ltd. The following publication Hong, T., Wang, S., Wang, F., & Wang, X. (2019, February). Study on the Optimization of PCM Integrated Air-Conditioning Duct for the Demand Shifting. In IOP Conference Series: Earth and Environmental Science (Vol. 238, No. 1, p. 012045). IOP Publishing is available at https://doi.org/10.1088/1755-1315/238/1/012045 |
Appears in Collections: | Conference Paper |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Hong_Study_Optimization_PCM.pdf | 951.01 kB | Adobe PDF | View/Open |
Page views
131
Last Week
2
2
Last month
Citations as of Mar 24, 2024
Downloads
75
Citations as of Mar 24, 2024
SCOPUSTM
Citations
1
Citations as of Mar 28, 2024
WEB OF SCIENCETM
Citations
1
Citations as of Mar 28, 2024
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.