Title: Modeling of the mechanical behavior of HA/PEEK biocomposite under quasi-static tensile load
Authors: Fan, JP
Tsui, CP 
Tang, CY 
Keywords: Finite element method (FEM)
HA/PEEK biocomposite
Interface debonding
Matrix damage
Particle volume fraction (PVF)
Unit-cell model
Issue Date: 2004
Publisher: Elsevier
Source: Materials science and engineering. A, Structural materials : properties, microstructure and processing, 2004, v. 382, no. 1-2, p. 341-350 How to cite?
Journal: Materials science and engineering. A, Structural materials : properties, microstructure and processing 
Abstract: A cylindrical three-phase unit-cell model was established for predicting mechanical properties of hydroxyapatite (HA)-reinforced polyetheretherketone (PEEK) biocomposite. The model consists of an elastic-brittle HA spherical particle, an elasto-plastic matrix, and a very thin interphase region between the particle and the matrix. Perfect bonding was initially assumed among three phases before occurrence of particle-matrix debonding. For simulation of the particle-matrix debonding process of HA/PEEK, a damage evolution equation was incorporated into the material properties of the interphase region. A ductile damage evolution in the matrix was also taken into account, and was treated as a criterion for the failure of the biocomposite. A user subroutine for the damage-coupled material properties for the matrix and the interphase region was built and incorporated into a finite element code named ABAQUS. The influence of interfacial adhesion on the non-linear stress-strain relation of HA/PEEK has also been simulated by varying the tensile strength of the interphase region. The strength of the interphase region in the composite could be estimated by a comparison between the predicted and experimental results. By using the unit-cell modeling technique incorporated with the stress-based debonding and the composite failure criterion and selection of appropriate interphase strength, the numerical simulation was found to be close to the experimental results from available literatures. In vivo performance of HA/PEEK as implant materials was also discussed.
URI: http://hdl.handle.net/10397/8018
ISSN: 0921-5093
EISSN: 1873-4936
DOI: 10.1016/j.msea.2004.04.078
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

25
Last Week
0
Last month
0
Citations as of Aug 17, 2017

WEB OF SCIENCETM
Citations

22
Last Week
0
Last month
0
Citations as of Jul 28, 2017

Page view(s)

34
Last Week
2
Last month
Checked on Aug 21, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.