Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/80131
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Applied Biology and Chemical Technology-
dc.creatorTam KY-
dc.creatorChau FT-
dc.date.accessioned2018-12-21T07:15:00Z-
dc.date.available2018-12-21T07:15:00Z-
dc.identifier.issn2090-8865-
dc.identifier.urihttp://hdl.handle.net/10397/80131-
dc.language.isoenen_US
dc.publisherHindawi Publishing Corporationen_US
dc.rightsCopyright © 1992 Hindawi Publishing Corporation. This is an open access article distributed under the Creative Commons Attribution License (https://creativecommons.org/licenses/by/3.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.(From Hindawi Publishing Corporation https://dx.doi.org/10.1155/S1463924692000294)en_US
dc.rights© 1992 Taylor & Francis Ltd (From Publisher pdf).en_US
dc.rightsThe following publication Tam, K. Y., & Chau, F. T. (1992). Simultaneous multiwavelength study of the reaction of phenolphthalein with sodium hydroxide. Journal of Automatic Chemistry, 14(5), 157-162 is available at https://dx.doi.org/10.1155/S1463924692000294en_US
dc.titleSimultaneous multiwavelength study of the reaction of phenolphthalein with sodium hydroxideen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage157-
dc.identifier.epage162-
dc.identifier.volume14-
dc.identifier.issue5-
dc.identifier.doi10.1155/S1463924692000294-
dcterms.abstractA photodiode array (PDA) spectrophotometer was used to study the fading reaction of phenolpthalein in dilute sodium hydroxide solution. The principal component analysis (PCA) method was employed to identify the number of light absorbing species in the kinetics system. The target factor analysis (TFA) procedure, coupled with the Broyden-Fletcher-Goldfard-Shanno (BFGS) optimization method, was applied to the observed data to deduce the rate constants and the concentration-time profile of the reaction. The internal referencing method was shown to be essential in improving the quality of data obtained by a single beam PDA spectrophotomer.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationJournal of automatic chemistry, 1992, v. 14, no. 5, p. 157-162-
dcterms.isPartOfJournal of automatic chemistry-
dcterms.issued1992-
dc.identifier.scopus2-s2.0-0027078504-
dc.identifier.pmid18924946-
dc.identifier.eissn2090-8873-
dc.description.validate201812 bcrc-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Tam_Simultaneous_Multiwavelength_Study.pdf2.07 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

205
Last Week
0
Last month
Citations as of Apr 21, 2024

Downloads

131
Citations as of Apr 21, 2024

SCOPUSTM   
Citations

9
Last Week
0
Last month
Citations as of Apr 19, 2024

WEB OF SCIENCETM
Citations

7
Last Week
0
Last month
Citations as of Apr 25, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.