Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/7800
Title: Experimental measurement and modeling of multi-winding high-voltage transformer
Authors: Zhou, J
Chen, Q
Ruan, X
Wong, SC 
Tse, CK 
Issue Date: 2008
Source: Proceedings of the 11th International Conference on Electrical Machines and Systems, ICEMS 2008, 2008, 4771572, p. 4411-4415 How to cite?
Abstract: A model of multi-winding high-voltage transformer is presented, which takes into account effects of leakage transformer, winding resistance and parasitic capacitance. The modeling method and the parameter determination procedure are applicable to all kinds of transformers. Using an LCR meter, all parameters, except the parasitic capacitance, can be determined from taking port impedance measurements. The parasitic capacitance can be calculated by considering the resonant circuit equations. Finally, the modeling approach and the parameter determination procedure have been illustrated experimentally with a 60 W 35 kHz high-voltage transformer. The port impedance simulations and measurements show good consistency in a wide frequency range from 10 kHz to 200 kHz.
Description: 11th International Conference on Electrical Machines and Systems, ICEMS 2008, Wuhan, 17-20 October 2008
URI: http://hdl.handle.net/10397/7800
ISBN: 9787506292214
Appears in Collections:Conference Paper

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

2
Last Week
0
Last month
Citations as of Feb 25, 2017

Page view(s)

29
Last Week
1
Last month
Checked on Aug 13, 2017

Google ScholarTM

Check



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.