Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/7522
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Rehabilitation Sciences-
dc.creatorFeng, Beibei-
dc.creatorPao, Wing-yi-
dc.creatorWu, Anna-
dc.creatorLi, Hercy Chi Kong-
dc.creatorLi-Tsang, Wai-ping Cecilia-
dc.date.accessioned2015-06-29T02:12:02Z-
dc.date.available2015-06-29T02:12:02Z-
dc.identifier.issn1569-1861-
dc.identifier.urihttp://hdl.handle.net/10397/7522-
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.rightsCopyright © 2013, Elsevier (Singapore) Pte. Ltd. All rights reserved.en_US
dc.rightsThe following publication "Feng, B., Pao, W. Y., Wu, A., Li, H. C. K., & Li-Tsang, C. W. P. (2013). Are "smart pressure monitored suits" "smarter" than conventional garments in clinical applications? Hong Kong Journal of Occupational Therapy, 23(2), 82-88" as it appears on Elsevier's ScienceDirect website (http://www.sciencedirect.com) is available at http://dx.doi.org/10.1016/j.hkjot.2013.11.002en_US
dc.rightsNOTICE: this is the author's version of a work that was accepted for publication in Hong Kong Journal of Occupational Therapy. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in PUBLICATION, VOL 23, ISSUE 2, December 2013 DOI 10.1016/j.hkjot.2013.11.002en_US
dc.subjectCompression stockingen_US
dc.subjectPressure therapyen_US
dc.subjectRehabilitationen_US
dc.titleAre "smart pressure monitored suits" "smarter" than conventional garments in clinical applications?en_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage82-
dc.identifier.epage88-
dc.identifier.volume23-
dc.identifier.issue2-
dc.identifier.doi10.1016/j.hkjot.2013.11.002-
dcterms.abstractSummary Objective/Background There is still no standardized regime to prescribe pressure garments with quantifiable pressure dosage to patients with different medical conditions. This study aimed to examine the efficacy of a newly developed system [a smart pressure monitored suit (SPMS)] for pressure intervention when compared with the conventional method of pressure garment production (conventional garment or CG). The SPMS is designed with a set of standard methods of measurements and computerized pattern drafting software (YUKA) to adjust the pressure range through computation of the percentage of strain directly on the drafted pattern. The CG was fabricated by occupational therapists in clinical settings.-
dcterms.abstractMethods A selected group of patients who required pressure therapy intervention was recruited through convenience sampling. They were provided with both a SPMS and a CG, each to be worn for 1 month. The interface pressure levels of both garments were measured before the implementation. Patients' feedback was collected using a standardized questionnaire on the comfort of wear, elasticity, and durability of the garments.-
dcterms.abstractResults There was a significant difference in the deterioration of pressure between the SPMSs and the CGs (p < .05) before and after 1 month of wear. The satisfaction on overall efficacy of the SPMSs was significantly higher than that of CGs (p < .05).-
dcterms.abstractConclusion This standardized system using a SPMS appeared to provide a more accurate and consistent pressure range and long-lasting effect to the patients. It also appeared to be more efficient and effective in terms of production and fabrication.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationHong Kong journal of occupational therapy, Dec. 2013, v. 23, no. 2, p. 82-88-
dcterms.isPartOfHong Kong journal of occupational therapy-
dcterms.issued2013-12-
dc.identifier.eissn1876-4398-
dc.identifier.rosgroupidr72655-
dc.description.ros2013-2014 > Academic research: refereed > Publication in refereed journal-
dc.description.oaAccepted Manuscripten_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
HKJOT-D-13-00011R1 (1).pdfPre-published version354.05 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

143
Last Week
0
Last month
Citations as of Apr 14, 2024

Downloads

161
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

6
Last Week
0
Last month
0
Citations as of Apr 19, 2024

WEB OF SCIENCETM
Citations

4
Last Week
0
Last month
0
Citations as of Apr 18, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.