Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/74752
Title: Concurrent multi-scale modeling of a transmission tower structure and its experimental verification
Authors: Wang, FY 
Xu, YL 
Zhan, S 
Keywords: Bolted connection
Comparison
Experiment
Multi-scale modeling
New multi-point constraints
Transmission tower
Issue Date: 2017
Publisher: Hong Kong Institute of Steel Construction
Source: Advanced steel construction, 2017, v. 13, no. 3, p. 258-272 How to cite?
Journal: Advanced steel construction 
Abstract: The interruption of electrical service due to failure of transmission tower structures can have devastating economic and social consequences. The current method for analyzing transmission tower structures is often to treat the angle members of the tower as either pin-ended truss elements or fix-ended beam elements. This approach ignores the effects of joint flexibility, local geometric and material nonlinearity, bolt slippage and deformation, making the structural analysis and design of the tower inadequate. In an effort to improve the structural analysis of transmission tower structures, this study aims at developing a multi-scale modeling method for transmission tower structures, in which critical joints of the tower are modeled using solid elements in a great detail while other members are modeled with common beam elements. The critical joint model includes gusset plates, angle members and bolts. The effects of local geometric and material nonlinearity and the contact problem between the bolts, plates and angles are all taken into consideration. New multi-point constraints for beam-to-solid connections at interface developed by the authors are used to couple the critical local joint model with the beam elements to form a multi-scale model of the tower. To verify the multi-scale modeling method, a physical model of a transmission tower structure was constructed and tested. The displacement and strain response of the tower model measured from the static tests are compared with the numerical results. The dynamic characteristics of the tower model identified from the dynamic tests are also compared with the numerical results. The comparative results show that the multi-scale modeling method is feasible and accurate for simultaneously predicting both global and local responses as well as estimating dynamic characteristics of the transmission tower structure.
URI: http://hdl.handle.net/10397/74752
ISSN: 1816-112X
DOI: 10.18057/IJASC.2017.13.3.4
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

2
Last Week
0
Last month
Citations as of Dec 7, 2018

WEB OF SCIENCETM
Citations

2
Last Week
0
Last month
Citations as of Dec 10, 2018

Page view(s)

24
Citations as of Dec 10, 2018

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.