Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/70047
Title: Development of an ergonomic handle for laparoscopic surgery
Authors: Lam, DKH
Huang, W
Keywords: Discomfort
Gripping position
Human hand
Human-centered design
Muscle fatigue
Issue Date: 2010
Publisher: springer
Source: IFMBE Proceedings, 2010, v. 31, p. 99-102 How to cite?
Journal: IFMBE Proceedings 
Abstract: The objective of this project was to develop an ergonomic laparoscopic instrument handle based on the dimensions of human hand in gripping position for reducing discomfort and muscle fatigue. Eight human subjects (4 male and 4 female; height: 172.5±10.5 cm; weight: 58.4±12.6 kg) were recruited. The statues of their right hands in gripping position were made by using Alginoplast powder and plaster. A 3D scanning machine was used to obtain digital images of the 8 hand statues for measurements. The following dimensions were recorded from the digital images: distance between the tip of thumb and the tip of last finger (81.2±10.2 mm), distance between the tip of thumb and the tip of ring finger (71.0±7.3 mm), distance between the tip of thumb and the tip of middle finger (63.2±9.5 mm), distance between the tip of thumb and the tip of index finger (50.8±10.2 mm), distance between “Hu Kou arc” and the bottom of middle phalanx in index finger (47.9±6.4 mm), angle between the thumb-middle finger line and the thumb-last finger line (36.1±7.6 degree), angle between the thumb-middle finger line and the thumb-ring finger line (19.3±3.8 degree), angle between the thumb-middle finger line and the thumb-index finger line (20.4±2.7 degree), and the distances from thumb to phalanx joint arc at -20° (61.2±10.4 mm), -10° (73.0±9.3 mm), 0° (assigned as the line between thumb and middle finger, 84.9±9.1 mm), 10° (91.5±7.4 mm), 20° (95.6±7.1 mm), 30° (98.8±8.8 mm), and 40° (101.6±11.3 mm). The mean dimensions were used to make a laparoscopic handle prototype, with special consideration on the thumb ring and the finger contact surface curvature based on the measurement. In conclusion, we demonstrated a new approach to develop an ergonomic laparoscopic instrument handle based on the dimensions of human hand in gripping position.
Description: International Federation for Medical and Biological Engineering Proceedings,Singapore, 1-6 August 2010
URI: http://hdl.handle.net/10397/70047
ISBN: 978-3-642-14514-8
978-3-642-14515-5
ISSN: 1867-5662
DOI: 10.1007/978-3-642-14515-5_26
Appears in Collections:Conference Paper

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

1
Citations as of Nov 19, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.