Please use this identifier to cite or link to this item:
Title: Induced surges in railway signaling systems during an indirect lightning strike
Authors: Qi, R
Li, B
Du, Y 
Keywords: FDTD
Signaling circuit
Issue Date: 2016
Publisher: Institute of Electrical and Electronics Engineers Inc.
Source: 2016 33rd International Conference on Lightning Protection, ICLP 2016, 2016, 7791498 How to cite?
Abstract: This paper presents a study of lightning induced surges in railway signaling systems with the FDTD method. During an indirect lightning strike, induced surges are observed in the outdoor circuits due to electric and magnetic coupling. The induced surge currents propagate along the signal cables towards the receiving equipment in railway stations. It is found that geometry of the outdoor lines, earthing and bonding practices affect induced surge currents and voltages in the circuits. Equipotential bonding can substantially reduce the induced surge voltage impinging on the equipment in railway stations.
Description: 33rd International Conference on Lightning Protection, ICLP 2016, Portugal, 25-30 September 2016
ISBN: 9781509058433
ISSN: 2469-8784
DOI: 10.1109/ICLP.2016.7791498
Appears in Collections:Conference Paper

View full-text via PolyU eLinks SFX Query
Show full item record

Page view(s)

Citations as of Mar 19, 2018

Google ScholarTM



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.