Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/64432
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Electrical Engineering-
dc.creatorDai, RC-
dc.creatorChan, KW-
dc.creatorSnider, LA-
dc.creatorZhang, BM-
dc.date.accessioned2017-02-22T07:34:36Z-
dc.date.available2017-02-22T07:34:36Z-
dc.identifier.issn1000-3673-
dc.identifier.urihttp://hdl.handle.net/10397/64432-
dc.language.isozhen_US
dc.publisher中國學術期刊(光盤版)電子雜誌社en_US
dc.rights© 2002 中国学术期刊电子杂志出版社。本内容的使用仅限于教育、科研之目的。en_US
dc.rights© 2002 China Academic Journal Electronic Publishing House. It is to be used strictly for educational and research purposes.en_US
dc.subjectElectromagnetic transient stabilityen_US
dc.subjectEMTPen_US
dc.subjectDistributed parametersen_US
dc.titleElectromagnetic transient stability simulation of long distance transmission line in DTSen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage7-
dc.identifier.epage10-
dc.identifier.volume26-
dc.identifier.issue7-
dcterms.abstractIn this paper a method for electromagnetic transient simulation of long distance high voltage alternating current (HVAC) power transmission line with uniform distributed parameters is put forward and the presented method is applied to dispatcher training simulator (DTS). To ensure the speed and accuracy of simulation an electromagnetic transient model for long distance HVAC transmission line with uniform distributed parameters is adopted and the hybrid transient simulation method in ordinary electromechanical transient model is still applied to the simulation of other parts of the power network. The results from simple calculation examples and practical examples show that the presented method is correct and effective.-
dcterms.accessRightsopen accessen_US
dcterms.alternativeDTS中長距離輸電線路的電磁暫態仿真-
dcterms.bibliographicCitation電網技術 (Power system technology), 2002, v. 26, no. 7, p. 7-10-
dcterms.isPartOf電網技術 (Power system technology)-
dcterms.issued2002-
dc.identifier.rosgroupidr11559-
dc.description.ros2002-2003 > Academic research: refereed > Publication in refereed journal-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Dai_Electromagnetic_Transient_Stability.pdf304.17 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

98
Last Week
0
Last month
Citations as of Apr 14, 2024

Downloads

21
Citations as of Apr 14, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.