Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/616
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Applied Physics-
dc.creatorGuo, S-
dc.creatorChan, HLW-
dc.creatorZhao, X-
dc.creatorChoy, CL-
dc.date.accessioned2014-12-11T08:28:16Z-
dc.date.available2014-12-11T08:28:16Z-
dc.identifier.issn0034-6748-
dc.identifier.urihttp://hdl.handle.net/10397/616-
dc.language.isoenen_US
dc.publisherAmerican Institute of Physicsen_US
dc.rights© 2003 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in S. Guo et al., Rev. Sci. Instrum. 74, 1285 (2003) and may be found at http://link.aip.org/link/?rsi/74/1285.en_US
dc.subjectPolymer filmsen_US
dc.subjectStrain sensorsen_US
dc.subjectExtensometersen_US
dc.subjectPiezoelectric transducersen_US
dc.titleFactors affecting the performance of the bimorph-based dilatometer for field induced strain measurement of polymer filmsen_US
dc.typeJournal/Magazine Articleen_US
dc.description.otherinformationAuthor name used in this publication: H. L. W. Chanen_US
dc.description.otherinformationAuthor name used in this publication: X.-Z. Zhaoen_US
dc.description.otherinformationAuthor name used in this publication: C. L. Choyen_US
dc.identifier.spage1285-
dc.identifier.epage1291-
dc.identifier.volume74-
dc.identifier.issue3-
dcterms.abstractThis article gives a detailed discussion about the design and performance of a bimorph-based dilatometer using different sensor heads and platforms both experimentally and theoretically. A current preamplifier in high-pass filter mode was used to optimize the signal and a protective circuit was introduced. The test results demonstrated that the best signal occurred when the lengths of stainless steel pin and bimorph were both 10.0 mm and that the resonant frequency was inversely proportional to the square of the sensor length. Some suggestions for reducing the noise and improving the sensitivity were also provided.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationReview of scientific instruments, Mar. 2003, v. 74, no. 3, p. 1285-1291-
dcterms.isPartOfReview of scientific instruments-
dcterms.issued2003-03-
dc.identifier.isiWOS:000181530300022-
dc.identifier.scopus2-s2.0-0037352001-
dc.identifier.eissn1089-7623-
dc.identifier.rosgroupidr15114-
dc.description.ros2002-2003 > Academic research: refereed > Publication in refereed journal-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
bimorph-based_03.pdf328.38 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

127
Last Week
1
Last month
Citations as of Mar 24, 2024

Downloads

198
Citations as of Mar 24, 2024

SCOPUSTM   
Citations

1
Last Week
0
Last month
0
Citations as of Mar 29, 2024

WEB OF SCIENCETM
Citations

1
Last Week
0
Last month
0
Citations as of Mar 28, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.