Title: Assessment of mechanical exhaust in preventing vertical cross-household infections associated with single-sided ventilation
Authors: Wu, Y
Niu, J 
Keywords: Buoyancy effects
CFD simulation
Cross-infection
Mechanical exhaust
Single-sided natural ventilation
Issue Date: 2016
Publisher: Pergamon Press
Source: Building and environment, 2016, v. 105, p. 307-316 How to cite?
Journal: Building and environment 
Abstract: Single-sided natural ventilation is an energy efficient ventilation strategy that could provide satisfactory indoor air quality and thermal comfort. However, one of its possible negative influences is the cross-infection between households due to the two-way airflow. The present study aims at assessing the efficacy of mechanical exhaust (ME) devices to eliminate this possible cross-infection. CFD method was employed to simulate the buoyancy driven single-sided natural ventilation and the cross-contamination. Different occupant behaviour scenarios, such as ME-on centrally or ME-on individually, were compared with the no-ME case. It is found that mechanical exhaust could reduce the outflow of indoor air and increase the inflow of fresh air. However, the weakened outflow tends to be more attached to the façade and the re-entry risk may be increased. As the exhaust rate is large enough, the two-way airflow will turn into one-way inflow, and accordingly the vertical cross-household infection can be avoided. With ME-on in both floors, a low exhaust rate of 5 h-1 could reduce the presence of the tracer from the lower floor in the upper floor by an order of magnitude. But if the ME is on only in one of the two floors, the re-entry of outflow to the upper floor may be aggravated at some specific exhaust rate. Therefore, in epidemic seasons, appealing residents to switch on their individual exhaust fans, or alternatively switching on a central exhaust system is recommended. The results will contribute to the control of airborne transmission infectious diseases in high-rise residential buildings.
URI: http://hdl.handle.net/10397/61666
ISSN: 0360-1323
EISSN: 1873-684X
DOI: 10.1016/j.buildenv.2016.06.005
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

3
Last Week
0
Last month
Citations as of Aug 14, 2017

WEB OF SCIENCETM
Citations

3
Last Week
0
Last month
Citations as of Aug 12, 2017

Page view(s)

27
Last Week
2
Last month
Checked on Aug 13, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.