Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/61612
Title: Ventilation of air-conditioned residential buildings : a case study in Hong Kong
Authors: Ai, ZT
Mak, CM 
Cui, DJ
Xue, P
Keywords: Carbon dioxide (CO2)
On-site measurements
Residential buildings
Room air conditioner
Ventilation
Issue Date: 2016
Publisher: Elsevier
Source: Energy and buildings, 2016, v. 127, p. 116-127 How to cite?
Journal: Energy and buildings 
Abstract: More and more studies reported that there were insufficient ventilation and excessive CO2 concentration in air-conditioned residential buildings, but few solutions were provided. This study investigates the overnight evolution of CO2 concentration in air-conditioned residential buildings and then focuses mainly on the evaluation of three ventilation strategies, including overnight natural ventilation, short-term mechanical ventilation and short-term natural ventilation. On-site measurements were conducted in a typical residential bedroom in Hong Kong in September. The indoor and outdoor CO2 concentration, air temperature and relative humidity as well as the outdoor wind speed during the measurements were analysed. Ventilation rates were calculated based on the time series of CO2 concentration. This study confirms that additional ventilation is usually needed in air-conditioned residential buildings. Overnight natural ventilation with even a small opening is associated with excessive energy consumption and deteriorated indoor thermal environment. Short-term natural ventilation strategies are inefficient and uncontrollable. Compared to the best short-term natural ventilation strategy, a reasonably designed short-term mechanical ventilation strategy requires only a 41% of ventilation period to complete one full replacement of indoor air and to reach a lower indoor CO2 concentration. Nighttime case studies and a theoretical analysis suggest that a few several-minute mechanical ventilation periods could potentially maintain an acceptable indoor air quality for a normal sleeping period of 8 h.
URI: http://hdl.handle.net/10397/61612
ISSN: 0378-7788
EISSN: 1872-6178
DOI: 10.1016/j.enbuild.2016.05.055
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

4
Last Week
0
Last month
Citations as of Aug 24, 2017

WEB OF SCIENCETM
Citations

3
Last Week
0
Last month
Citations as of Aug 20, 2017

Page view(s)

18
Last Week
0
Last month
Checked on Aug 20, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.