Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/60899
DC Field | Value | Language |
---|---|---|
dc.contributor | Department of Building Services Engineering | - |
dc.creator | Meng, H | - |
dc.creator | Long, WD | - |
dc.creator | Wang, SW | - |
dc.date.accessioned | 2016-12-19T08:53:19Z | - |
dc.date.available | 2016-12-19T08:53:19Z | - |
dc.identifier.issn | 1002-8501 | - |
dc.identifier.uri | http://hdl.handle.net/10397/60899 | - |
dc.language.iso | zh | en_US |
dc.publisher | 中國學術期刊(光盤版)電子雜誌社 | en_US |
dc.rights | © 2005 中国学术期刊电子杂志出版社。本内容的使用仅限于教育、科研之目的。 | en_US |
dc.rights | © 2005 China Academic Journal Electronic Publishing House. It is to be used strictly for educational and research use. | en_US |
dc.subject | Central air conditioning | en_US |
dc.subject | Chilled water system | en_US |
dc.subject | Supervisory controller | en_US |
dc.subject | Real time control | en_US |
dc.title | Real time control of chilled water supervisory controller in central air conditioning systems | en_US |
dc.type | Journal/Magazine Article | en_US |
dc.identifier.spage | 96 | - |
dc.identifier.epage | 100, 136 | - |
dc.identifier.volume | 35 | - |
dc.identifier.issue | 11 | - |
dcterms.abstract | 针对集中空调冷水侧基本自动控制系统,设计了两个上位机控制器,分别仅对供回水压差和同时对压差与冷水供水温度进行实时优化;通过仿真实验分析了控制器对系统控制稳定性和系统能耗的影响。结果表明,综合考虑制冷机和二次泵系统的上位机控制器具有较好的可实施性,能在保证系统运行稳定的前提下减少冷水侧能耗。 | - |
dcterms.abstract | From the viewpoint of basic automatic control system, designs two chilled water supervisory controllers and applies them to digital simulators to real time control of the supply/return pressure difference and of both the difference and the supply chilled water temperature. Analyses the influences of the supervisory controller on control stability and energy consumption of the system by simulation experiment. The simulation results show that the controller making trade off between chillers and chilled water pumps is practicable in saving the total energy of chilled water system while still keeping the control stability. | - |
dcterms.accessRights | open access | en_US |
dcterms.alternative | 集中空调冷水侧局部系统上位机控制器的实时控制分析 | - |
dcterms.bibliographicCitation | 暖通空調 (HV & A), 2005, v. 35, no. 11, p. 96-100, 136 | - |
dcterms.isPartOf | 暖通空調 (HV & A) | - |
dcterms.issued | 2005 | - |
dc.identifier.rosgroupid | r29252 | - |
dc.description.ros | 2005-2006 > Academic research: refereed > Publication in refereed journal | - |
dc.description.oa | Version of Record | en_US |
dc.identifier.FolderNumber | OA_IR/PIRA | en_US |
dc.description.pubStatus | Published | en_US |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
r29252.pdf | 672.59 kB | Adobe PDF | View/Open |
Page views
197
Last Week
2
2
Last month
Citations as of Apr 14, 2024
Downloads
70
Citations as of Apr 14, 2024
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.