Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/60272
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Electrical Engineering-
dc.creatorLi, X-
dc.creatorDing, Y-
dc.creatorMacalpine, JMK-
dc.creatorLi, ZY-
dc.date.accessioned2016-11-21T02:36:29Z-
dc.date.available2016-11-21T02:36:29Z-
dc.identifier.issn1003-8337-
dc.identifier.urihttp://hdl.handle.net/10397/60272-
dc.language.isozhen_US
dc.publisher中國學術期刊 (光盤版) 電子雜誌社en_US
dc.rights© 2001 中国学术期刊电子杂志出版社。本内容的使用仅限于教育、科研之目的。en_US
dc.rights© 2001 China Academic Journal Electronic Publishing House. It is to be used strictly for educational and research purposes.en_US
dc.subjectInsulatoren_US
dc.subjectPollutionen_US
dc.subjectSurface conductanceen_US
dc.titleSurface conductance of polluted glass sheet in fog chamberen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage3-
dc.identifier.epage6-
dc.identifier.issue2-
dc.identifier.doi10.16188/j.isa.1003-8337.2001.02.001-
dcterms.abstract输配电系统中 ,污秽的绝缘外表面在潮湿天气所发生的沿面闪络是引起输电线路故障的主要原因之一。加强对绝缘表面在此种情况下电导特性的基础研究 ,有助于进一步探究表面电导与污秽闪络的关系 ,有利于进行较为准确的绝缘在线监测工作。并可根据研究结果 ,采取相应措施以改进绝缘防污性能、进行有针对性的清洗、检修及更换等 ,以达到减少污闪事故的发生率、保障供电可靠性和安全性的目的。本文以污秽玻璃片为实验对象 ,在人工雾室中对其表面电导特性进行了大量的基础实验 ,得到了相关的实验结果。通过对实验结果的分析和总结 ,得到了一些有益的结论-
dcterms.abstractIn the power transmission and distribution system, the power supply failure caused by the polluted flashover of insulator has been becoming one of the most serious factors, especially under moist weather.Taking the polluted glass sheet as experimental subject, we have measured its surface conductance in fog chamber and obtained a large number of experimental data.Through analyzing and summarizing the experimental data, we have gained useful conclusions which are helpful for the insulation monitoring on line, model building and so on.-
dcterms.accessRightsopen accessen_US
dcterms.alternative污秽绝缘表面电导特性的研究-
dcterms.bibliographicCitation电瓷避雷器 (Insulators and surge arresters), 2001, no. 2, p. 3-6-
dcterms.isPartOf电瓷避雷器 (Insulators and surge arresters)-
dcterms.issued2001-
dc.identifier.rosgroupidr10964-
dc.description.ros2001-2002 > Academic research: refereed > Publication in refereed journal-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
r10964.pdf149.07 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

71
Last Week
1
Last month
Citations as of Apr 21, 2024

Downloads

106
Citations as of Apr 21, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.