Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/5858
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Applied Physics-
dc.contributorDepartment of Health Technology and Informatics-
dc.creatorQiu, W-
dc.creatorChen, Y-
dc.creatorCheng, WF-
dc.creatorYu, Y-
dc.creatorTsang, FK-
dc.creatorDai, J-
dc.creatorZhou, Q-
dc.creatorSun, L-
dc.date.accessioned2014-12-11T08:25:10Z-
dc.date.available2014-12-11T08:25:10Z-
dc.identifier.urihttp://hdl.handle.net/10397/5858-
dc.language.isoenen_US
dc.publisherHong Kong Institute of Acoustics (HKIOA)en_US
dc.rights© Hong Kong Institute of Acoustics (HKIOA)en_US
dc.rightsPosted with permission of the publisher.en_US
dc.titleAn open system for intravascular ultrasound imagingen_US
dc.typeConference Paperen_US
dc.description.otherinformationAuthor name used in this publication: Cheng, Wang Faien_US
dc.description.otherinformationInvited conference paperen_US
dcterms.abstractCardiovascular disease is the main causes of morbidity and mortality due to lumen stenosis and atherosclerosis. Intravascular ultrasound (IVUS) is able to delineate internal structures of vessel wall with fine spatial resolution. However, IVUS is insufficient to identify the fibrous cap thickness and tissue composition of atherosclerotic lesions, the key factors to stage atherosclerosis and determine appropriate treatment strategies. Currently, novel techniques have been developed to determine tissue composition, which require an open IVUS system to accommodate these techniques for comprehensive plaque characterization. This paper presents the development of such an IVUS system with reconfigurable hardware implementation, programmable image processing algorithms, and flexible imaging control to support an easy fusion with other techniques to improve the diagnostic capabilities for cardiovascular diseases. In addition, this IVUS utilized a miniaturized ultrasound transducer constructed by PMN-PT single crystal for better piezoelectric constant and electromechanical coupling coefficient than traditional PZT ceramics. Testing results showed that the IVUS system could offer a minimum detectable signal of 25µV, allowing a 51dB dynamic range at 47dB gain, with a frequency range from 20MHz to 80MHz. Finally, phantom imaging and in vitro vessel imaging were conducted to demonstrate the performance of the open system for IVUS applications.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationPaper presented at the Acoustics 2012 Hong Kong, 13-18 May 2012, Hong Kong-
dcterms.issued2012-
dc.identifier.isiWOS:000310896600009-
dc.identifier.rosgroupidr60256-
dc.description.ros2011-2012 > Academic research: refereed > Invited conference paper-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Conference Paper
Files in This Item:
File Description SizeFormat 
Qiu_an_open_system.pdf593.51 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Show simple item record

Page views

148
Last Week
2
Last month
Citations as of Apr 14, 2024

Downloads

175
Citations as of Apr 14, 2024

WEB OF SCIENCETM
Citations

22
Last Week
1
Last month
0
Citations as of Apr 18, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.