Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/5834
DC Field | Value | Language |
---|---|---|
dc.contributor | Department of Rehabilitation Sciences | - |
dc.creator | Kot, BCW | - |
dc.creator | Zhang, ZJ | - |
dc.creator | Lee, AWC | - |
dc.creator | Leung, VYF | - |
dc.creator | Fu, SN | - |
dc.date.accessioned | 2014-12-11T08:23:23Z | - |
dc.date.available | 2014-12-11T08:23:23Z | - |
dc.identifier.uri | http://hdl.handle.net/10397/5834 | - |
dc.language.iso | en | en_US |
dc.publisher | Public Library of Science | en_US |
dc.rights | © Kot et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. | en_US |
dc.subject | Magnetic-resonance elastography | en_US |
dc.subject | Skeletal-muscle | en_US |
dc.subject | Healthy | en_US |
dc.title | Elastic modulus of muscle and tendon with shear wave ultrasound elastography : variations with different technical settings | en_US |
dc.type | Journal/Magazine Article | en_US |
dc.description.otherinformation | Author name used in this publication: Brian Chin Wing Kot | en_US |
dc.identifier.spage | 1 | - |
dc.identifier.epage | 6 | - |
dc.identifier.volume | 7 | - |
dc.identifier.issue | 8 | - |
dc.identifier.doi | 10.1371/journal.pone.0044348 | - |
dcterms.abstract | Standardization on Shear wave ultrasound elastography (SWUE) technical settings will not only ensure that the results are accurate, but also detect any differences over time that may be attributed to true physiological changes. The present study evaluated the variations of elastic modulus of muscle and tendon using SWUE when different technical aspects were altered. The results of this study indicated that variations of elastic modulus of muscle and tendon were found when different transducer's pressure and region of interest (ROI)'s size were applied. No significant differences in elastic modulus of the rectus femoris muscle and patellar tendon were found with different acquisition times of the SWUE sonogram. The SWUE on the muscle and tendon should be performed with the lightest transducer's pressure, a shorter acquisition time for the SWUE sonogram, while measuring the mean elastic modulus regardless the ROI's size. | - |
dcterms.accessRights | open access | en_US |
dcterms.bibliographicCitation | PLoS one, 31 Aug., 2012, v. 7, no. 8, e44348, p. 1-6 | - |
dcterms.isPartOf | PLoS one | - |
dcterms.issued | 2012-08-31 | - |
dc.identifier.isi | WOS:000308221300084 | - |
dc.identifier.scopus | 2-s2.0-84865651823 | - |
dc.identifier.pmid | 22952961 | - |
dc.identifier.eissn | 1932-6203 | - |
dc.description.oa | Version of Record | en_US |
dc.identifier.FolderNumber | OA_IR/PIRA | en_US |
dc.description.pubStatus | Published | en_US |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Kot_Elastic_Modulus_Muscle.pdf | 584.58 kB | Adobe PDF | View/Open |
Page views
139
Last Week
1
1
Last month
Citations as of Apr 14, 2024
Downloads
147
Citations as of Apr 14, 2024
SCOPUSTM
Citations
236
Last Week
3
3
Last month
2
2
Citations as of Apr 5, 2024
WEB OF SCIENCETM
Citations
228
Last Week
1
1
Last month
3
3
Citations as of Apr 18, 2024
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.