Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/55462
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Biomedical Engineering-
dc.creatorWang, Q-
dc.creatorLi, M-
dc.creatorLou, EHM-
dc.creatorWong, MS-
dc.date.accessioned2016-09-07T02:21:52Z-
dc.date.available2016-09-07T02:21:52Z-
dc.identifier.urihttp://hdl.handle.net/10397/55462-
dc.language.isoenen_US
dc.publisherPublic Library of Scienceen_US
dc.rights© 2015 Wang et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.en_US
dc.rightsThe following publication: Wang Q, Li M, Lou EHM, Wong MS (2015) Reliability and Validity Study of Clinical Ultrasound Imaging on Lateral Curvature of Adolescent Idiopathic Scoliosis. PLoS ONE 10(8): e0135264 is available at https://doi.org/10.1371/journal.pone.0135264en_US
dc.titleReliability and validity study of clinical ultrasound imaging on lateral curvature of adolescent idiopathic scoliosisen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume10en_US
dc.identifier.issue8en_US
dc.identifier.doi10.1371/journal.pone.0135264en_US
dcterms.abstractBackground: Non-ionizing radiation imaging assessment has been advocated for the patients with adolescent idiopathic scoliosis (AIS). As one of the radiation-free methods, ultrasound imaging has gained growing attention in scoliosis assessment over the past decade. The center of laminae (COL) method has been proposed to measure the spinal curvature in the coronal plane of ultrasound image. However, the reliability and validity of this ultrasound method have not been validated in the clinical setting.-
dcterms.abstractObjectives: To evaluate the reliability and validity of clinical ultrasound imaging on lateral curvature measurements of AIS with their corresponding magnetic resonance imaging (MRI) measurements.-
dcterms.abstractMethods: Thirty curves (ranged 10.2°-68.2°) from sixteen patients with AIS were eligible for this study. The ultrasound scan was performed using a 3-D ultrasound unit within the same morning of MRI examination. Two researchers were involved in data collection of these two examinations. The COL method was used to measure the coronal curvature in ultrasound image, compared with the Cobb method in MRI. The intra-and inter-rater reliability of the COL method was evaluated by intra-class correlation coefficient (ICC). The validity of this method was analyzed by paired Student's t-test, Bland-Altman statistics and Pearson correlation coefficient. The level of significance was set as 0.05.-
dcterms.abstractResults: The COL method showed high intra-and inter-rater reliabilities (both with ICC (2, K) >0.9, p<0.05) to measure the coronal curvature.compared with Cobb method, COL method showed no significant difference (p<0.05) when measuring coronal curvature. Furthermore, Bland-Altman method demonstrated an agreement between these two methods, and Pearson's correlation coefficient (r) was high (r>0.9, p<0.05).-
dcterms.abstractConclusion: The ultrasound imaging could provide a reliable and valid measurement of spinal curvature in the coronal plane using the COL method. Further research is needed to validate the proposed ultrasound measurement in larger clinical trial and to optimize the ultrasound scanning and measuring procedure.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationPLoS one, 2015, v. 10, no. 8, e0135264-
dcterms.isPartOfPLoS one-
dcterms.issued2015-
dc.identifier.scopus2-s2.0-84942897437-
dc.identifier.pmid26266802-
dc.identifier.eissn1932-6203en_US
dc.identifier.rosgroupid2015003627-
dc.description.ros2015-2016 > Academic research: refereed > Publication in refereed journalen_US
dc.description.validate201810_a bcmaen_US
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Wang_Reliability_validity_study.PDF7.59 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

141
Last Week
1
Last month
Citations as of Apr 21, 2024

Downloads

97
Citations as of Apr 21, 2024

SCOPUSTM   
Citations

45
Last Week
0
Last month
Citations as of Apr 19, 2024

WEB OF SCIENCETM
Citations

38
Last Week
0
Last month
Citations as of Apr 25, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.