Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/4657
Title: Design of a transcutaneous power regulator for artificial hearts
Authors: Tang, Kam-Cheung
Keywords: Heart, Artificial -- Power supply.
Digital control systems.
Electronic controllers.
Hong Kong Polytechnic University -- Dissertations
Issue Date: 2011
Publisher: The Hong Kong Polytechnic University
Abstract: A high-efficiency transcutaneous power regulator for artificial hearts with pulse-width-modulation phase-locked-loop (PWM-PLL) control has been built with a digital signal processor (DSP) as the primary side controller, and a new method of sensing the output voltage inside the human body utilizing the same power transcutaneous transformer as the medium for signal transmission is introduced. The feedback signal is modulated in the secondary in a frequency band above the PWM-PLL cut-off frequency and below the converter switching frequency. In this way, the feedback signal can be demodulated from the primary current that can be measured. A SPICE macromodel for the double-tuned resonant converter is developed to help design the control loop and the selection of modulation-demodulation frequency bands. A hardware prototype using a single-chip DSP together with analog filters was built and the control software was implemented in DSP program codes. A phase-locked-loop (PLL) switching frequency locking function is constructed by using an on-chip analog comparator. It saves extra hardware for the PLL control. Using a DSP controller, closed-loop stability control can be implemented as software codes and digital control algorithms are used in the system design. The steady-state voltage loop control algorithm uses a modified PI controller with input voltage feed-forward. Another software module is added to shorten the time of output voltage transient in the event of an output load change. This algorithm is based on the response characteristics of the primary side inductor current and output loading estimation. The power efficiency of the regulator system is optimized by setting the switching frequency close to the resonant point. The resulting efficiency is between 87% and 94% for the output load power from 12W to 60W. For a more restricted output power range commonly used by artificial heart systems (15W - 35W), the power efficiency is over 90% for all loads.
Description: ix, 116 leaves : ill. (some col.) ; 30 cm.
PolyU Library Call No.: [THS] LG51 .H577M EIE 2011 TangK
URI: http://hdl.handle.net/10397/4657
Rights: All rights reserved.
Appears in Collections:Thesis

Files in This Item:
File Description SizeFormat 
b24562464_link.htmFor PolyU Users 162 BHTMLView/Open
b24562464_ir.pdfFor All Users (Non-printable) 2.68 MBAdobe PDFView/Open
Show full item record

Page view(s)

514
Last Week
4
Last month
Checked on Jul 9, 2017

Download(s)

784
Checked on Jul 9, 2017

Google ScholarTM

Check



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.