Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/44055
Title: Computer-aided diagnosis for distinguishing pancreatic mucinous cystic neoplasms from serous oligocystic adenomas in spectral CT images
Authors: Li, C
Lin, X
Hui, C
Lam, KM 
Zhang, S
Keywords: Computer-aided diagnosis
Dual-energy spectral CT
Mucinous cystic neoplasm
Serous oligocystic adenoma
Support vector machine
Issue Date: 2016
Publisher: SAGE Publications
Source: Technology in cancer research and treatment, 2016, v. 15, no. 1, p. 44-54 How to cite?
Journal: Technology in cancer research and treatment 
Abstract: Objective: This preliminary study aims to verify the effectiveness of the additional information provided by spectral computed tomography (CT) with the proposed computer-aided diagnosis (CAD) scheme to differentiate pancreatic serous oligocystic adenomas (SOAs) from mucinous cystic neoplasms of pancreas cystic lesions. Materials and Methods: This study was conducted from January 2010 to October 2013. Twenty-three patients (5 men and 18 women; mean age, 43.96 years old) with SOA and 19 patients (3 men and 16 women; mean age, 41.74 years old) with MCN were included in this retrospective study. Two types of features were collected by dual-energy spectral CT imaging as follows: conventional and additional quantitative spectral CT features. Classification results of the CAD scheme were compared using the conventional features and full feature data set. Important features were selected using support vector machine classification method combined with feature-selection technique. The optimal cutoff values of selected features were determined through receiver–operating characteristic curve analyses. Results: Combining conventional features with additional spectral CT features improved the overall accuracy from 88.37% to 93.02%. The selected features of the proposed CAD scheme were tumor size, contour, location, and low-energy CT values (43 keV). Iodine–water basis material pair densities in both arterial phase (AP) and portal venous phase (PP) were important factors for differential diagnosis of SOA and MCN. The optimal cutoff values of long axis, short axis, 40 keV monochromatic CT value in AP, iodine (water) density in AP, 43 keV monochromatic CT value in PP, and iodine (water) density in PP were 3.4 mm, 3.1 mm, 35.7 Hu, 0.32533 mg/mL, 39.4 Hu, and 0.348 mg/mL, respectively. Conclusion: The combination of conventional features and additional information provided by dual-energy spectral CT shows a high accuracy in the CAD scheme. The quantitative information of spectral CT may prove useful in the diagnosis and classification of SOAs and MCNs with machine learning algorithms.
URI: http://hdl.handle.net/10397/44055
ISSN: 1533-0346
DOI: 10.1177/1533034614563013
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page view(s)

48
Last Week
1
Last month
Checked on Aug 21, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.