Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/43414
Title: On-site measurement of tracer gas transmission between horizontal adjacent flats in residential building and cross-infection risk assessment
Authors: Wu, Y
Tung, TCW
Niu, JL 
Keywords: Air infiltration
Airborne transmission
Infection risk
On-site measurement
Residential building
Tracer gas
Issue Date: 2016
Publisher: Pergamon Press
Source: Building and environment, 2016, v. 99, p. 13-21 How to cite?
Journal: Building and environment 
Abstract: Airborne transmission is a main spread mode of respiratory infectious diseases, whose frequent epidemic has brought serious social burden. Identifying possible routes of the airborne transmission and predicting the potential infection risk are meaningful for infectious disease control. In the present study, an internal spread route between horizontal adjacent flats induced by air infiltration was investigated. On-site measurements were conducted, and tracer gas technique was employed. Two measurement scenarios, closed window mode and open window mode, were compared. Using the calculated air change rate and mass fraction, the cross-infection risk was estimated using the Wells-Riley model. It found that tracer gas concentrations in receptor rooms are one order lower than the source room, and the infection risks are also one order lower. Opening windows results in larger air change rate on the one hand, but higher mass fraction on the other hand. Higher mass fraction not necessarily results in higher infection risk as the pathogen concentration in the source room is reduced by the higher air change rate. In the present study, opening windows could significantly reduce the infection risk of the index room but slightly reduce the risks in receptor rooms. The mass fraction of air originated from the index room to the receptor units could be 0.28 and the relative cross-infection risk through the internal transmission route could be 9%, which are higher than the external spread through single-sided window flush. The study implicates that the horizontal transmission route induced by air infiltration should not be underestimated.
URI: http://hdl.handle.net/10397/43414
ISSN: 0360-1323
EISSN: 1873-684X
DOI: 10.1016/j.buildenv.2016.01.013
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

5
Last Week
0
Last month
Citations as of Jul 14, 2017

WEB OF SCIENCETM
Citations

4
Last Week
0
Last month
Citations as of Jun 10, 2017

Page view(s)

20
Last Week
1
Last month
Checked on Jul 9, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.