Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/43402
Title: A robust signal preprocessing framework for wrist pulse analysis
Authors: Wang, D
Zhang, D 
Lu, G
Keywords: Intra-class distance
Period segmentation
Wavelet-based decomposition
Wrist pulse preprocessing
Issue Date: 2016
Publisher: Elsevier
Source: Biomedical signal processing and control, 2016, v. 23, 720, p. 62-75 How to cite?
Journal: Biomedical signal processing and control 
Abstract: Wrist pulse has been a physical health indicator in Traditional Chinese Medicine (TCM) for a long history. With the development of sensor technology and bioinformatics, quantifying pulse diagnosis by using signal processing technology is attracting increasing attentions in recent years. Since wrist pulse signals collected by the sensors are often corrupted by artifacts in real situations, many approaches on the wrist pulse preprocessing including pulse de-noising and baseline wander removal are introduced for more accurate wrist pulse analysis. However, these scattered methods are incomplete with some limitations when used to preprocess our special pulse data for the clinical applications. This paper presents a robust signal preprocessing framework for wrist pulse analysis. The cascade filter based on frequency-dependent analysis (FDA) is first introduced to remove the high frequency noises and to select the significant pulse intervals. Then the curve fitting method is developed to adjust the direction and the baseline drift with minimum signal distortion. Last, the period segmentation and pulse normalization is applied for the feature extraction. The effectiveness of the proposed pulse preprocessing is validated through experiments on actual pulse records with biochemical markers. In contrast with the traditional methods, the proposed preprocessing framework is effective in extracting more accurate pulse features. And the highest classification rate 91.6% is obtained on diabetes diagnosis. The results demonstrate that our method is superior to the former pulse preprocessing researches and practical for wrist pulse analysis.
URI: http://hdl.handle.net/10397/43402
ISSN: 1746-8094
DOI: 10.1016/j.bspc.2015.08.002
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

4
Last Week
0
Last month
Citations as of Sep 24, 2017

WEB OF SCIENCETM
Citations

4
Last Week
0
Last month
Citations as of Sep 20, 2017

Page view(s)

47
Last Week
0
Last month
Checked on Sep 24, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.