Title: Application of Building Information Model (BIM) in building thermal comfort and energy consumption analysis
Authors: Li, Yiye
Keywords: Heating
Buildings -- Energy conservation
Buildings -- Environmental engineering
Hong Kong Polytechnic University -- Dissertations
Issue Date: 2011
Publisher: The Hong Kong Polytechnic University
Abstract: Building Information Modelling (BIM) is an emerging technological and procedural shift within the Architecture, Engineering, Construction and Operations (AECO) industry, it is argued to be a catalyst for improving efficiency/effectiveness and lowering the high costs of inadequate interpretability (Succar 2009). However, the interoperability of different Building Performance Analysis (BPA) tools is still an area under development. Building Performance Analysis (BPA) tools, such as Ecotect, IES<VE>, eQuest, Energy Plus, Design Builder, and HEED, have been traditionally applied to study the energy performance of buildings for design of more sustainable and energy efficient buildings. This study aims at exploring the significance and barriers of information delivery between BIM and BPA tools (Ecotect, eQUEST, GBS), and exploring how to apply BIM model to building thermal comfort and energy consumption analysis. Two tests have been done for that purpose. In Test I, three product models, with different detail level and file sizes, were built and delivered from Revit Architecture into ECOTECT, and eQUEST. Comparison studies of three file formats and the two programmes were conducted to guide the further integration analysis. In Test II, a thermal comfort analysis and an energy saving analysis for building envelope were conducted separately in Ecotect and eQUEST. Interventions and specific customisations of the model organisations were recorded during the analysis. PMV average values of three typical floors (6F/19F/32F) were calculated, and the result shows that thermal comfort in typical seasons is acceptable for those three floors. Annual electricity consumption of HVAC system was also calculated based on different building envelope design strategies. Significances, barriers and recommendations for integration design with BIM and BPA tools are also concluded.
Description: vii, 107 leaves : ill. ; 30 cm.
PolyU Library Call No.: [THS] LG51 .H577M BRE 2011 Li
URI: http://hdl.handle.net/10397/4301
Rights: All rights reserved.
Appears in Collections:Thesis

Files in This Item:
File Description SizeFormat 
b24415820_link.htmFor PolyU Users 162 BHTMLView/Open
b24415820_ir.pdfFor All Users (Non-printable) 2.55 MBAdobe PDFView/Open
Show full item record

Page view(s)

1,727
Last Week
13
Last month
Checked on Apr 23, 2017

Download(s)

1,274
Checked on Apr 23, 2017

Google ScholarTM

Check



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.