Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/35758
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Biomedical Engineering-
dc.creatorJi, CH-
dc.creatorYu, JH-
dc.creatorLi, TJ-
dc.creatorTian, L-
dc.creatorHuang, YF-
dc.creatorWang, YY-
dc.creatorZheng, YP-
dc.date.accessioned2016-04-15T08:35:28Z-
dc.date.available2016-04-15T08:35:28Z-
dc.identifier.issn1475-925X-
dc.identifier.urihttp://hdl.handle.net/10397/35758-
dc.language.isoenen_US
dc.publisherBioMed Centralen_US
dc.rights© 2015 Ji etal. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.en_US
dc.rightsThe following publication Ji, C. H., Yu, J. H., Li, T. J., Tian, L., Huang, Y. F., Wang, Y. Y., & Zheng, Y. P. (2015). Dynamic curvature topography for evaluating the anterior corneal surface change with Corvis ST. Biomedical Engineering Online, 14, 53, 1-16 is available at https://dx.doi.org/10.1186/s12938-015-0036-2en_US
dc.subjectDynamic parameteren_US
dc.subjectSegmentationen_US
dc.subjectCorneaen_US
dc.subjectCorvis STen_US
dc.titleDynamic curvature topography for evaluating the anterior corneal surface change with Corvis STen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.epage16-
dc.identifier.volume14-
dc.identifier.doi10.1186/s12938-015-0036-2-
dcterms.abstractBackground: The measurement of dynamic parameters, such as the length of applanation and the amplitude of deformation, is significant for evaluating corneal properties. Most of the corneal properties (related to shape) including the anterior corneal curvature and the thickness of cornea can be easily measured using some existing techniques. However, they only provide the static or pseudo-dynamic analysis. Based on Corvis ST images, the dynamic features after corneal boundaries detection and parameter estimation will be helpful for corneal analysis. Material: The study included 40 eyes in normal group (ranging from 19 to 45 years old) and 30 eyes in keratoconus group (ranging from 16 to 40 years old). These eyes were examined by Corvis ST and for each one a sequence of 140 images was obtained. Besides, 11 subjects of each group were also tested by Pentacam.-
dcterms.abstractMethods: By analyzing the video from the Corvis ST imaging, the fully dynamic curvature topography is proposed to evaluate the response of the anterior corneal surface to the air puff. The new method not only quantitatively measures the intact variation of anterior corneal surface but also provides an intuitive way to observe the dynamic change of the anterior corneal surface in the whole air stream process. The proposed method consists of three main steps: cornea segmentation, curvature estimation and integrated visualization. An automatic segmentation method based on the combination of prior knowledge with phase symmetry and asymmetry theory is firstly presented to detect the corneal boundaries. The Landau-new method is then used to estimate the anterior corneal surface. The corneal dynamic topography is finally obtained by combining the dynamic parameters with the original Corvis ST video, which is an improvement of the fusion technique proposed by Li et al.-
dcterms.abstractResults and conclusion: By comparing the segmentation results with manual method and built-in method of Corvis ST, the accuracy and robustness of our proposed segmentation method is demonstrated. The correctness of the estimated corneal anterior curvatures is also evaluated by comparing it with that of Pentacam which is considered to be able to provide the first-class measurement currently. The dynamic topography may be used to distinguish the dynamic behavior of normal corneas from that of keratoconus.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationBiomedical engineering online, 2015, v. 14, 53, p. 1-16-
dcterms.isPartOfBiomedical engineering online-
dcterms.issued2015-
dc.identifier.isiWOS:000355902000001-
dc.identifier.scopus2-s2.0-84930365198-
dc.identifier.pmid26040948-
dc.identifier.artn53-
dc.identifier.rosgroupid2014004767-
dc.description.ros2014-2015 > Academic research: refereed > Publication in refereed journal-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Ji_Dynamic_Curvature_Topography.pdf1.3 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

178
Last Week
1
Last month
Citations as of Apr 14, 2024

Downloads

96
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

20
Last Week
0
Last month
Citations as of Apr 12, 2024

WEB OF SCIENCETM
Citations

18
Last Week
0
Last month
Citations as of Apr 18, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.