Title: Investigation of indoor and outdoor air quality at classrooms in Hong Kong
Authors: Chang, Chia-chi Maureen
Keywords: Classrooms -- Environmental aspects -- China -- Hong Kong
Air quality -- China -- Hong Kong
Indoor air pollution -- China -- Hong Kong
Hong Kong Polytechnic University -- Dissertations
Issue Date: 2000
Publisher: The Hong Kong Polytechnic University
Abstract: An investigation of the indoor and outdoor air qualities at classrooms in Hong Kong was carried out. Classrooms chosen were located in industrial, residential, urban, and rural areas. Pollutions and parameters studied were temperature, relative humidity, carbon dioxide (CO₂), sulfur dioxide, nitrogen oxides, volatile organic compounds, particulate matter with diameter less than 10 microns (PM₁₀), particulate matter with diameter less than 2.5 microns (PM₂.₅), formaldehde, carbon monoxide, and bacteria. The effect of ventilation rate on pollutant concentration was also investigated. Indoor and outdoor PM₁₀ concentrations were high mainly due to vehicle exhaust emissions and construction activities. High PM₁₀ concentrations (200 μg/m³) were observed during classroom cleaning because sweeping of the floor re-suspended particulate matters settled on the ground into the air. Higher CO₂ concentrations, with averages over 1000 ppm, were found at classrooms with mechanical ventilation than those classrooms with natural ventilation. All of the maximum CO₂ concentrations in the classrooms were higher than the American Society for Heating, Refrigerating and Air-conditioning Engineers (ASHRAE) standard of 1000 ppm due to very high occupancy (over 60 person/100 m²) and inadequate ventilation. Maximum CO₂ level of 5900 ppm measured at an air-conditioned classroom because the door and windows were closed and ventilation was shut off. Ventilation rates measured at the naturally ventilated classroom and the air-conditioned classroom were 0.937 air changes per hour (ACH) and 0.217 ACH respectively. The ventilation rates were below the ASHRAE Standard 62-1989 of 7.5 l/s. Results from the control study agreed with those in the previous studies that pollutants with outdoor sources had lower indoor concentrations than the outdoors in an air-conditioned classroom. The air-conditioners, though not providing enough fresh air, could be barriers for outdoor pollutants. Therefore air-conditioning in classrooms can provide a quiet learning environment for children, and also provide a thermally comfortable environment, and lower concentrations of pollutants but not adversely affecting indoor air quality. Improvements in air exchange rates with installation of air cleaning devices can provide a more comfortable learning environment for students.
Description: xii, 100, [30] leaves : ill. (some col.) ; 30 cm.
PolyU Library Call No.: [THS] LG51 .H577M CSE 2000 Chang
URI: http://hdl.handle.net/10397/3449
Rights: All rights reserved.
Appears in Collections:Thesis

Files in This Item:
File Description SizeFormat 
b15320315_link.htmFor PolyU Users 161 BHTMLView/Open
b15320315_ir.pdfFor All Users (Non-printable) 5.07 MBAdobe PDFView/Open
Show full item record

Page view(s)

552
Last Week
3
Last month
Checked on May 28, 2017

Download(s)

253
Checked on May 28, 2017

Google ScholarTM

Check



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.