Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/32951
Title: PEG adsorption of autoantibodies and detection of alloantibodies in warm autoimmune hemolytic anemia
Authors: Cheng, CK
Wong, ML
Lee, AW
Issue Date: 2001
Publisher: Amer Assoc Blood Banks
Source: Transfusion, 2001, v. 41, no. 1, p. 13-17 How to cite?
Journal: Transfusion 
Abstract: BACKGROUND: The purpose of this study was to evaluate the effectiveness of PEG in the adsorption of autoantibodies and the detection of alloantibodies in patients with warm autoimmune hemolytic anemia (WAIHA). STUDY DESIGN AND METHODS: The study was divided into three parts. First, the effectiveness of antibody removal by a conventional adsorption procedure and that by the PEG adsorption method were compared by using commercial antisera adsorbed with antigen-positive RBCs. Second, patients' sera with known weak alloanti-E were used to test against screening cells after allogeneic adsorption to show nonspecific coating of antibodies and the dilution effect on the PEG adsorption procedure. Third, conventional and PEG one-cell sample allogeneic adsorptions of WAIHA patients' sera with and without alloantibodies were performed and compared. RESULTS: In the first part, seven of the eight polyclonal antisera gave a lower titer and score when tested against antigen-positive RBCs in the indirect antiglobulin test; this indicated that PEG is more efficient in removing antibodies. In the second part, similar reaction patterns were observed in antibody screening tests on unadsorbed sera and on sera after the first, second, and third adsorptions, which indicated that there was no alloantibody loss, nonspecific antibody coating, or dilution effect when PEG was added in the allogeneic adsorption procedures. In the third part, a 40-percent increase in efficiency in reducing the number of adsorptions and an 85-percent decrease in completion time of the adsorption procedures were obtained when PEG was used for adsorbing sera from 16 patients with WAIHA. Both conventional and PEG procedures were capable of removing autoantibodies to identify the specificities of alloantibodies. CONCLUSION: The PEG adsorption method is an effective, sensitive, and efficient method of enhancing autoantibody adsorption and alloantibody detection. It can reduce the processing time and minimize the delay of urgent transfusions to patients with WAIHA and can indirectly enhance cost-effectiveness and decrease the labor-intensive testing required by these cases.
URI: http://hdl.handle.net/10397/32951
ISSN: 0041-1132
DOI: 10.1046/j.1537-2995.2001.41010013.x
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

14
Last Week
0
Last month
0
Citations as of Jul 17, 2017

WEB OF SCIENCETM
Citations

7
Last Week
0
Last month
0
Citations as of Jul 15, 2017

Page view(s)

31
Last Week
1
Last month
Checked on Jul 9, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.