Abstract: Background: The pulsatile ocular blood flow (POBF) of patients with asymmetric internal carotid artery (ICA) stenosis was measured bilaterally. The purpose of this study was to investigate the sensitivity of POBF assessments in screening for ICA stenosis. Methods: Seventeen subjects with asymmetric ICA stenosis confirmed with carotid duplex ultrasound were recruited. The diagnoses of ICA stenosis were categorised into less than 50 per cent, 50 to 69 per cent and 70 per cent or greater. Their POBF and ocular dimensions were measured after local anaesthesia. Twenty-three normal healthy subjects were recruited as the control. All of the subjects had an inter-ocular axial length difference of less than one millimetre. Results: There were 14 males and three females in the patient group with a median age of 74 years. Fourteen patients had reduced POBF to the eye ipsilateral on the side with greater ICA stenosis. The reduction in POBF ranged from 3.1 to 49.2 per cent. Two patients had reduced POBF contralateral to the side with greater ICA stenosis. One patient had similar POBF between the eyes. The control group included six males and 17 females with a median age of 65 years. The difference in their POBF between the eyes ranged from 0.3 to 13.0 per cent. Conclusions: Stenosis of the internal carotid artery was found to reduce the POBF ipsilateral to the side with greater stenosis. The overlap in the difference in inter-ocular POBF between the patient and control groups led to a low sensitivity (calculated as 41.2 per cent) for screening ICA stenosis from an assessment of POBF. Therefore, POBF assessment is not a good diagnostic tool for screening for ICA stenosis.
URI: http://hdl.handle.net/10397/32947
ISSN: 0816-4622
EISSN: 1444-0938
DOI: 10.1111/j.1444-0938.2005.tb05104.x
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

2
Last Week
0
Last month
0
Citations as of Nov 18, 2017

Page view(s)

40
Last Week
1
Last month
Checked on Nov 20, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.