Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/32561
Title: Adsorption heat pump using an innovative coupling refrigeration cycle
Authors: Wang, S 
Zhu, D
Keywords: Adsorption heat pump
Binary coupling
Thermodynamics and operating pressure
Issue Date: 2004
Source: Adsorption, 2004, v. 10, no. 1, p. 47-55 How to cite?
Journal: Adsorption 
Abstract: An adsorption heat pump system using a new binary coupling adsorptive cycle is developed and tested. Experimental results show that the COP of the binary coupling cycle is higher than that of a pure zeolite-water system. The system operating pressure is found to be moderate (close to the ambient pressure) when a proper concentration of ammonia is used in the system. The moderate operating pressure of the new coupling cycle results in low leakage to the system, achieving long life and the light design of the system vessels. The use of the new binary adsorption cycle greatly improves the feasibility and reliability of the adsorption heat pumps, providing essential benefits for the industrialisation of adsorption heat pumps.
URI: http://hdl.handle.net/10397/32561
ISSN: 0929-5607
DOI: 10.1023/B:ADSO.0000024034.39430.94
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

11
Last Week
0
Last month
0
Citations as of Oct 9, 2017

WEB OF SCIENCETM
Citations

13
Last Week
0
Last month
0
Citations as of Oct 17, 2017

Page view(s)

48
Last Week
0
Last month
Checked on Oct 15, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.