Title: Evaluation of the Morse Fall Scale : applicability in Chinese hospital populations
Authors: Chow, SKY 
Lai, CKY 
Wong, TKS
Suen, LKP
Kong, SKF 
Chan, CK 
Wong, IYC
Keywords: Chinese hospital population
Morse Fall Scale
Reliability
Validity
Issue Date: 2007
Publisher: Pergamon-Elsevier Science Ltd
Source: International journal of nursing studies, 2007, v. 44, no. 4, p. 556-565 How to cite?
Journal: International Journal of Nursing Studies 
Abstract: Background: Patient falls have been identified as a significant health problem in the general hospital patient population. The Morse Fall Scale (MFS) is an individualized criterion-referenced assessment tool designed for measuring the likelihood of patient falls in hospitals. Despite the scale has demonstrated high validity and reliability in the previous researches, this study is to provide additional validity tests to determine the applicability in the Chinese hospital population. Objectives: To examine the predictive power of the MFS to predict patient falls. To conduct reliability tests on internal consistency, item analysis, inter-rater and test-retest reliability. Design: The study was a cross-sectional study. Settings: The medical and geriatric units of three rehabilitation hospitals in Hong Kong participated in the study. Participants: A convenience sample of 954 Chinese patients was recruited sequentially upon admission in the hospital ward units. They ranged in age from 17 to 100 years, with a mean of 70.2 years. Methods: The patients were assessed for fall risk using the MFS on admission. Data was collected on the number of patients who fell rather than the number of falls. Results: The scale had a sensitivity of 31% and a specificity of 83% when the cut-off point was determined at 45. The field test demonstrated excellent inter-rater reliability with an ICC value of 0.97 (95%CI 0.94-0.98). Repeatability was high with an ICC of 0.98 (95% CI 0.98-0.99). The evaluation revealed a low Cronbach's alpha coefficient and a low to moderate item-to-scale correlation. Conclusions: The evidence collected in this study has shown both the positive and negative aspects of using the MFS in assessing the fall risk of Chinese patients during rehabilitation. The discriminative validity and internal consistency reliability provide researchers and clinicians with a major step in further developing or modifying the scale.
URI: http://hdl.handle.net/10397/32004
DOI: 10.1016/j.ijnurstu.2005.12.003
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

21
Last Week
0
Last month
1
Citations as of Feb 23, 2017

WEB OF SCIENCETM
Citations

18
Last Week
0
Last month
0
Citations as of Feb 22, 2017

Page view(s)

40
Last Week
0
Last month
Checked on Feb 26, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.