Title: Comparison of noninvasive tear break-up time measurements from black and white background instruments
Authors: Cho, P 
Ho, KY
Huang, YC
Chui, HY
Kwan, MC
Keywords: Agreement
Background color
Correlation
Noninvasive tear break-up time
Issue Date: 2004
Publisher: Lippincott Williams & Wilkins
Source: Optometry and vision science, 2004, v. 81, no. 6, p. 436-441 How to cite?
Journal: Optometry and vision science 
Abstract: Purpose. To compare noninvasive tear break-up time (NITBUT) measured using a black background instrument (NITBUTb) and that measured using a white background instrument (NITBUTw). Methods. The NITBUTb and NITBUTw of the right eye of 58 asymptomatic subjects aged 16 to 23 years were measured by the same examiner on the same day and compared. NITBUT measurement was terminated at 45 s to minimize ocular discomfort and reflex tearing. Results. Three subjects had reflex tearing during the NITBUT measurement, and nine subjects had either NITBUTb or NITBUTw values >45 s, so their data were excluded. For the 46 subjects with NITBUT ≤45 s, no significant difference between NITBUTb and NITBUTw was found (Wilcoxon test p = 0.156). No statistically significant relationship was found between NITBUTb and NITBUTw (Spearman r = 0.217, p = 0.147). The agreement between NITBUTb and NITBUTw was poor, with a mean difference of 1.3 s and 95% limits of agreement of -20.0 to +22.6 s. Conclusions. There was no significant difference in NITBUT made from instruments of different backgrounds if the procedures and endpoint criterion were the same. The poor agreement between NITBUTb and NITBUTw was due to the large variations in NITBUT rather than the difference in the background color of the instrument used. However, use of the black background instrument for subjects with dark irides is recommended, as it is relatively easier to see the grid image on the eye and >50% of our subjects complained of discomfort from glare with the white background instrument.
URI: http://hdl.handle.net/10397/31797
ISSN: 1040-5488
EISSN: 1538-9235
DOI: 10.1097/01.opx.0000135095.15125.05
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

12
Last Week
0
Last month
0
Citations as of Nov 18, 2017

WEB OF SCIENCETM
Citations

12
Last Week
0
Last month
0
Citations as of Nov 15, 2017

Page view(s)

40
Last Week
1
Last month
Checked on Nov 13, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.