Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/31616
Title: Analysis of lightning-induced impulse magnetic fields in the building with an insulated down conductor
Authors: Du, YP 
Zhou, QB
Keywords: Building
Coaxial cable
Impulse magnetic field
Lightning protection system
Issue Date: 2006
Source: IEEJ transactions on fundamentals and materials, 2006, v. 126, no. 2, p. 71-77 How to cite?
Journal: IEEJ Transactions on Fundamentals and Materials 
Abstract: This paper presents an analysis of lightning-induced magnetic fields in a building. The building of concern is protected by the lightning protection system with an insulated down conductor. In this paper a system model for metallic structure of the building is constructed first using the circuit approach. The circuit model of the insulated down conductor is discussed extensively, and explicit expressions of the circuit parameters are presented. The system model was verified experimentally in the laboratory. The modeling approach is applied to analyze the impulse magnetic fields in a full-scale building during a direct lightning strike. It is found that the impulse magnetic field is significantly high near the down conductor. The field is attenuated if the down conductor is moved to a column in the building. The field can be reduced further if the down conductor is housed in an earthed metal pipe. Recommendations for protecting critical equipment against lightning-induced magnetic fields are also provided in the paper.
URI: http://hdl.handle.net/10397/31616
ISSN: 0385-4205
DOI: 10.1541/ieejfms.126.71
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

2
Last Week
0
Last month
0
Citations as of Sep 11, 2017

Page view(s)

38
Last Week
4
Last month
Checked on Sep 17, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.